OSHA Inspection: RDO EQUIPMENT CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RDO EQUIPMENT CO. in 2801 NORTH LOUISE AVENUE, SIOUX FALLS, SD 57107 (NAICS 423830). OSHA activity number 347053183.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RDO Equipment CO. — free Get an email when a new federal OSHA severe-injury report for RDO Equipment CO. is published. One employer, no account, unsubscribe in one click.
Establishment
RDO EQUIPMENT CO.
Site address
2801 NORTH LOUISE AVENUE
City
SIOUX FALLS
State
SD
ZIP
57107
Mailing
2801 NORTH LOUISE AVENUE, SIOUX FALLS, SD 57107
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Apr 3, 2024
Abate by
May 3, 2024
Penalty
Initial $12,445 · Current $12,445
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   (a)RDO Equipment Co., at 2801 North Louise Avenue, Sioux Falls, SD 57107: On or about and at times prior to October 3, 2023, the employer did not ensure that machine specific procedural steps for shutting down, isolating, blocking and securing machines or equipment was utilized when maintenance activities were being conducted on the JRI parts washer  to control hazardous energy. This condition exposed employees to  stored energy sources.  Abatement Note:  The procedures shall include but are not limited to the following:  (1)	A specific statement of the intended use of the procedures;  (2)	Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  (3)	Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  (4)	Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (O) $12445
  • — Z (S) $12445

1910.242 B

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Apr 3, 2024
Abate by
May 3, 2024
Penalty
Initial $6,222 · Current $0 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a)RDO Equipment Co., at 2801 North Louise Avenue, Sioux Falls, SD 57107: On or about and at times prior to October 23, 2023, the employer did not ensure that compressed air nozzles used for cleaning within the maintenance area were reduced to less than 30p.s.i.  This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6222

1910.305 B01 II

Other-than-serious Gravity 1 1 instance 5 exposed
Issued
Apr 3, 2024
Abate by
May 3, 2024
Penalty
Initial $6,222 · Current $3,734 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) RDO Equipment Co., at 2801 North Louise Avenue, Sioux Falls, SD 57107: On or about and at times prior to October 23, 2023, the employer did not ensure that two unused openings (knockouts) on the portable 240 volt two-gang receptable in Bay 1 of the maintenance shop were effectively closed.  This condition exposed employees to burn and shock hazards.
Recent events (2)
  • — I (O) $3734
  • — Z (S) $6222

1910.303 G01 I

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Apr 3, 2024
Abate by
May 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:  (a)RDO Equipment Co., at 2801 North Louise Avenue, Sioux Falls, SD 57107: On or about and at times prior to October 23, 2023, the employer did not ensure that adequate clearance around electrical panel #1 in the new shop area of the facility, on the north wall in that the electrical panel was impeded by equipment and materials stored in front of the panel. This condition exposed employees to the hazard of electrical shock and burns.  (b)RDO Equipment Co., at 2801 North Louise Avenue, Sioux Falls, SD 57107: On or about and at times prior to October 23, 2023, the employer did not ensure that adequate clearance around electrical panel #2 in the new shop area of the facility, on the north wall in that the electrical panel was impeded by equipment and materials stored in front of the panel. This condition exposed employees to the hazard of electrical shock and burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View RDO Equipment CO.'s full OSHA safety record →