Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JZNEE RENEWABLE ENERGY TECHNOLOGY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JZNEE RENEWABLE ENERGY TECHNOLOGY INC. in 12001 NORTH HOUSTON ROSSLYN RD., HOUSTON, TX 77086 (NAICS 221114). OSHA activity number 347060691.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jznee Renewable Energy Technology INC. — free Get an email when a new federal OSHA severe-injury report for Jznee Renewable Energy Technology INC. is published. One employer, no account, unsubscribe in one click.
Site address
12001 NORTH HOUSTON ROSSLYN RD.
City
HOUSTON
State
TX
ZIP
77086
Mailing
12001 NORTH HOUSTON ROSSLYN RD., HOUSTON, TX 77086
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
58
Ownership type
A

9 citations on file for this inspection.

1910.28 B03 I A

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $9,680 · Current $3,872 Reduced
29 CFR  1910.28(b)(3)(i)(A): The employer did not ensure that each employee on a walking-working surface was protected from falling into any hole or pit that was 4 feet (1.2 m) or more above a lower level by a cover or covers:   On or about October 25, 2023,   in the Coil Line 1 area,   the employees were exposed to fall hazards when working near an open pit that was 4 feet deep without a cover.
Recent events (3)
  • — F (S) $3872
  • — C (S) $9680
  • — Z (S) $9680

1910.28 B11 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $6,453 · Current $2,581 Reduced
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements.  On or about October 25, 2023, in the Dust Control System Area, employees were exposed to fall hazards when checking filters by climbing a flight of stairs that was not equipped with a stair rail systems and handrails.
Recent events (3)
  • — F (S) $2581.2
  • — C (S) $6453
  • — Z (S) $6453

1910.29 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2024
Abate by
Apr 8, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.29(b)(3): The employer did not ensure that guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail.  On or about October 25, 2023, in the Dust Collector System Area, employees were exposed to fall hazards when checking filters when accessing the platform that was not equipped with a guardrail system capable of withstanding a force of at least 200 pounds .
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.106 E02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $11,292 · Current $4,517 Reduced
29 CFR 1910.106(e)(2)(ii):  Flammable or combustible liquids were not stored in tanks or closed containers:   On or about October 25, 2023,  in Building 2,   the employees were using flammable and combustible liquids such a spray paints and not storing in closed containers.
Recent events (3)
  • — F (S) $4516.8
  • — C (S) $11292
  • — Z (S) $11292

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $11,292 · Current $4,517 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about October 25, 2023,   in the coil line area 1 and 2; the employees were exposed to struck-by hazards while walking and working around unguarded moving uncoiled metal.  a:   Coil Line 1,   employees were exposed to struck-by hazards while inspecting the line.   b:  Coil Line 2,   employees were exposed to struck-by hazards while inspecting the line.
Recent events (3)
  • — F (S) $4516.8
  • — C (S) $11292
  • — Z (S) $11292

1910.219 C02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $11,292 · Current $4,517 Reduced
29 CFR  1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  On or about October 25, 2023,  in the Coil Line 1 area,  the employees were exposed to caught-in hazards while working near unguarded rotating horizontal shafting less than 7 feet from floor.
Recent events (3)
  • — F (S) $4516.8
  • — C (S) $11292
  • — Z (S) $11292

1910.219 F03

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $11,292 · Current $4,517 Reduced
29 CFR  1910.219(f)(3):Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  On or about October 25. 2023,   Building ,  Area #165 in the uncoiling area,  the employees were exposed to caught-in hazards where unguarded chain and sprocket was located less than 7 feet above the floor.
Recent events (3)
  • — F (S) $4516.8
  • — C (S) $11292
  • — Z (S) $11292

1910.252 B02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 21, 2024
Abate by
Sep 26, 2024
Penalty
Initial $8,067 · Current $3,227 Reduced
29 CFR  1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  On or about October 25, 2023,   on Coil Line 1,   the employees were exposed to welding rays when walking next to the Coil Line 1 area where an employee was welding on the steel  without a protective shield.
Recent events (3)
  • — F (S) $3226.8
  • — C (S) $8067
  • — Z (S) $8067

1910.1200 E01

Other-than-serious 1 instance 59 exposed
Issued
Feb 21, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(f)     On or about October 25, 2023,  the employer did not develop and implement a written hazard communication program that identified  chemicals that were hazardous and were handle by employees.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Jznee Renewable Energy Technology INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347060691.