HOUSTON, TX —
OSHA Inspection: JZNEE RENEWABLE ENERGY TECHNOLOGY INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JZNEE RENEWABLE ENERGY TECHNOLOGY INC. in 12001 NORTH HOUSTON ROSSLYN RD., HOUSTON, TX 77086 (NAICS 221114). OSHA activity number 347060691.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JZNEE RENEWABLE ENERGY TECHNOLOGY INC.
- Site address
- 12001 NORTH HOUSTON ROSSLYN RD.
- City
- HOUSTON
- State
- TX
- ZIP
- 77086
- Mailing
- 12001 NORTH HOUSTON ROSSLYN RD., HOUSTON, TX 77086
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221114
- Employees
- 58
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B03 I A
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $9,680 · Current $3,872 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(i)(A): The employer did not ensure that each employee on a walking-working surface was protected from falling into any hole or pit that was 4 feet (1.2 m) or more above a lower level by a cover or covers: On or about October 25, 2023, in the Coil Line 1 area, the employees were exposed to fall hazards when working near an open pit that was 4 feet deep without a cover.
Recent events (3)
- — F (S) $3872
- — C (S) $9680
- — Z (S) $9680
1910.28 B11 II
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $6,453 · Current $2,581 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements. On or about October 25, 2023, in the Dust Control System Area, employees were exposed to fall hazards when checking filters by climbing a flight of stairs that was not equipped with a stair rail systems and handrails.
Recent events (3)
- — F (S) $2581.2
- — C (S) $6453
- — Z (S) $6453
1910.29 B03
- Issued
- Feb 21, 2024
- Abate by
- Apr 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(3): The employer did not ensure that guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail. On or about October 25, 2023, in the Dust Collector System Area, employees were exposed to fall hazards when checking filters when accessing the platform that was not equipped with a guardrail system capable of withstanding a force of at least 200 pounds .
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.106 E02 II
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $11,292 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii): Flammable or combustible liquids were not stored in tanks or closed containers: On or about October 25, 2023, in Building 2, the employees were using flammable and combustible liquids such a spray paints and not storing in closed containers.
Recent events (3)
- — F (S) $4516.8
- — C (S) $11292
- — Z (S) $11292
1910.212 A01
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $11,292 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 25, 2023, in the coil line area 1 and 2; the employees were exposed to struck-by hazards while walking and working around unguarded moving uncoiled metal. a: Coil Line 1, employees were exposed to struck-by hazards while inspecting the line. b: Coil Line 2, employees were exposed to struck-by hazards while inspecting the line.
Recent events (3)
- — F (S) $4516.8
- — C (S) $11292
- — Z (S) $11292
1910.219 C02 I
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $11,292 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about October 25, 2023, in the Coil Line 1 area, the employees were exposed to caught-in hazards while working near unguarded rotating horizontal shafting less than 7 feet from floor.
Recent events (3)
- — F (S) $4516.8
- — C (S) $11292
- — Z (S) $11292
1910.219 F03
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $11,292 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.219(f)(3):Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about October 25. 2023, Building , Area #165 in the uncoiling area, the employees were exposed to caught-in hazards where unguarded chain and sprocket was located less than 7 feet above the floor.
Recent events (3)
- — F (S) $4516.8
- — C (S) $11292
- — Z (S) $11292
1910.252 B02 III
- Issued
- Feb 21, 2024
- Abate by
- Sep 26, 2024
- Penalty
- Initial $8,067 · Current $3,227 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: On or about October 25, 2023, on Coil Line 1, the employees were exposed to welding rays when walking next to the Coil Line 1 area where an employee was welding on the steel without a protective shield.
Recent events (3)
- — F (S) $3226.8
- — C (S) $8067
- — Z (S) $8067
1910.1200 E01
- Issued
- Feb 21, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(f) On or about October 25, 2023, the employer did not develop and implement a written hazard communication program that identified chemicals that were hazardous and were handle by employees.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Jznee Renewable Energy Technology INC.
View Jznee Renewable Energy Technology INC.'s full OSHA safety record →
More inspections in this industry (NAICS 221114)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347060691.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.