Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: A&J ROOFING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A&J ROOFING CORPORATION in 340 GREEN ST., SOMONAUK, IL 60552 (NAICS 238160). OSHA activity number 347070088.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&J Roofing Corporation for free Get an email when a new federal OSHA severe-injury report for A&J Roofing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
340 GREEN ST.
City
SOMONAUK
State
IL
ZIP
60552
Mailing
960 MASON AVENUE, AURORA, IL 60506
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
Private (A)

4 citations on file for this inspection.

1903.19 D01

Other-than-serious 2 instances 4 exposed
Issued
Mar 28, 2024
Abate by
May 16, 2024
Penalty
Initial $388 · Current $388
29 CFR  1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  A&J Roofing Corporation DBA A&J Roofing Experts. failed to submit documents to OSHA within 10 calendar days after the abatement date verifying  that each of the following cited violations had been corrected:  Citation Number                      Item  Number                 Abatement Date 01                                                    01                                       02/26/2024 02                                                    02                                       02/26/2024   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • · Z (O) $388

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 26, 2024
Abate by
Feb 26, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about October 31, 2023 the employer failed to ensure the ladder used to access and egress the residential roof was 3 foot above the landing edge.  The ladder that is being used by the employees that were conducting residential roofing activities did not extend 3 feet above the landing edge.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • · Z (S) $3457

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Jan 26, 2024
Penalty
Initial $24,197 · Current $24,197
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  On or about October 31, 2023 the employer did not ensure that employees who were engaged in residential construction activities were protected from fall hazards.   Employees were exposed to falls in excess of 6 feet to the ground below while performing roofing activities.  A & J Roofing Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1497412, citation number 1, item number 1 and was affirmed as a final order on December 18, 2020, with respect to a workplace located at 154 Norfolk Avenue, Clarendon Hills, IL 60514.  No abatement documentation is required for this item.
Recent events (1)
  • · Z (R) $24197

1926.503 B01

Repeat 1 instance 6 exposed
Issued
Jan 26, 2024
Abate by
Feb 26, 2024
Penalty
Initial $346 · Current $346
29 CFR  1926.503(b)(1):The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.  On or about October 31, 2023 the employer failed to certify that employees had been trained to recognize and minimize fall hazards. Employees were exposed to fall hazards in excess of 6 feet while performing roofing activities on a residential structure without using fall protection.   A & J Roofing Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1497412, citation number 1, item number 1 and was affirmed as a final order on December 18, 2020, with respect to a workplace located at 154 Norfolk Avenue, Clarendon Hills, IL 60514.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • · Z (R) $346

View A&J Roofing Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347070088.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.