GAINESVILLE, GA —
OSHA Inspection: SALVADOR LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SALVADOR LOPEZ in LOT 55 COOL SPRINGS ROAD, GAINESVILLE, GA 30506 (NAICS 238170). OSHA activity number 347086076.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALVADOR LOPEZ
- Site address
- LOT 55 COOL SPRINGS ROAD
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30506
- Mailing
- 2208 HUTCHINS ROAD, LAWRENCEVILLE, GA 30044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B05 II
- Issued
- Dec 19, 2023
- Penalty
- Initial $2,679 · Current $1,607 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) New residential construction located at Lot # 55 Cool Springs Road, Gainesville, GA 30506. Side of structure: On or about 11/7/2023, the employer exposed employees to fall hazards of approximately 14-feet, 7-inches to the lower ground level, in that a fall protection system was not used while an employee accessed the cantilevered end of the scaffold platform.
Recent events (2)
- — I (S) $1607.4
- — Z (S) $2679
1926.451 B07
- Issued
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur only over supports, and/or was less than 12 inches (30 cm) when the platforms were not nailed together or otherwise restrained to prevent movement. a) New residential construction located at Lot # 55 Cool Springs Road, Gainesville, GA 30506. Side of structure: On or about 11/07/2023, the employer exposed employees to collapse/fall hazards of approximately 14-feet, 7 inches to the lower ground level, in that the bridged scaffold was not erected on the supporting pole and the scaffold platform was attached using rachet straps which is prohibited by the manufacturer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Dec 19, 2023
- Penalty
- Initial $2,679 · Current $1,607 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) New residential construction located at Lot # 55 Cool Springs Road, Gainesville, GA 30506. Side of structure: On or about 11/7/2023, the employer exposed employees to fall hazards of approximately 14-feet, 7-inches to the lower ground level, in that a fall protection system was not used while working from a pump jack scaffold system used to install siding.
Recent events (2)
- — I (S) $1607.4
- — Z (S) $2679
1926.451 C02
- Issued
- Dec 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) New residential construction located at Lot # 55 Cool Springs Road, Gainesville, GA 30506. Side of structure: On or about 11/07/2023, the employer exposed employees to potential collapse/ fall hazards of approximately 14-feet, 7 inches to the lower ground level, in that the scaffold supports were not resting on a mud sill or adequate firm foundation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Salvador Lopez
View Salvador Lopez's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347086076.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.