Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STATER BROS. MARKETS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STATER BROS. MARKETS in 69255 EAST RAMON ROAD, CATHEDRAL CITY, CA 92234 (NAICS 445110). OSHA activity number 347091399.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stater Bros. Markets — free Get an email when a new federal OSHA severe-injury report for Stater Bros. Markets is published. One employer, no account, unsubscribe in one click.
Site address
69255 EAST RAMON ROAD
City
CATHEDRAL CITY
State
CA
ZIP
92234
Mailing
69255 EAST RAMON ROAD, CATHEDRAL CITY, CA 92234
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.23 B10

Serious Gravity 5 1 instance 25 exposed
Issued
Dec 18, 2023
Abate by
Jan 23, 2024
Penalty
Initial $7,590 · Current $5,313 Reduced
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects as immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with � 1910.145 and removed from service until repaired in accordance with � 1910.22(d), or replaced.  Receiving back room: On and/or before November 07, 2023, employee(s) used a Warner 8ft fiber glass ladder with worn and illegible maximum load rating labels. The employer did not immediately tag defective ladders with "Dangerous: Do Not Use" or with other similar language. Employee(s) were exposed to ladder overloading, mechanical failure and/or fall hazard(s).
Recent events (2)
  • — I (S) $5313
  • — Z (S) $7590

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 18, 2023
Abate by
Jan 23, 2024
Penalty
Initial $11,385 · Current $7,970 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Receiving Cage: On and/or before November 7, 2023, a brown flexible cord was used to power an APC Surge arrest personal relocatable power tap, Dell computer screen, Dell computer, Oki printer, and Zebra MT365. The brown flexible cord and APC Surge arrest were not used according to listing labeling instructions. This condition potentially exposed employee(s) to electrical shock and/or fire hazards.
Recent events (2)
  • — I (S) $7970
  • — Z (S) $11385

1910.22 A03

Other-than-serious 1 instance 7 exposed
Issued
Dec 18, 2023
Abate by
Jan 30, 2024
Penalty
Initial $1,065 · Current $746 Reduced
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  Produce Cooler and Adjacent area: On and/or before November 07, 2023, employee(s) moved produce in/out of the produce cooler. The employer did not ensure ensure walking working surfaces were maintained free of water from melting produce. Employee(s) were potentially exposed to slip, trip, and fall hazard(s).
Recent events (2)
  • — I (O) $746
  • — Z (O) $1065

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Dec 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Warehousing section under stair case: On and/or before November 7, 2023, an Amerex Model 500 fire extinguisher was not readily accessible and was blocked by an aluminum cart. Employee(s) were potentially exposed to fire hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 7 exposed
Issued
Dec 18, 2023
Abate by
Jan 30, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Janitor's Room next to Bakery door: On and/or before November 7, 2023, employee(s) stored various chemicals such as Spill Magic in front of the circuit breaker panel. This condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stater Bros. Markets's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347091399.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.