Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NOVARES US ENGINE COMPONENTS INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NOVARES US ENGINE COMPONENTS INC in 850 WISCONSIN STREET, WALWORTH, WI 53184 (NAICS 326199). OSHA activity number 347121360.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Novares US Engine Components INC — free Get an email when a new federal OSHA severe-injury report for Novares US Engine Components INC is published. One employer, no account, unsubscribe in one click.
Site address
850 WISCONSIN STREET
City
WALWORTH
State
WI
ZIP
53184
Mailing
850 WISCONSIN STREET, WALWORTH, WI 53184
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
140
Ownership type
A

3 citations on file for this inspection.

1910.95 G06

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 24, 2024
Abate by
Feb 7, 2024
Penalty
Initial $9,795 · Current $6,244 Reduced

Hazardous substances 8111

29 CFR  1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :   An annual audiometric testing program was not established and maintained by making annual audiometric testing available for instances such as, but not limited to:  a) On November 29, 2023, operator #1 working on line #437 was exposed to noise at an 8-hour TWA exposure of 90.4 decibels.
Recent events (2)
  • — I (S) $6244
  • — Z (S) $9795

1910.95 K02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 24, 2024
Abate by
Feb 7, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program:    a) On November 29, 2023, operator #1 working on line #437 was exposed to noise at an 8-hour TWA exposure of 90.4 decibels was last trained during their initial training which was over a year ago from the overexposure date.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A04

Other-than-serious 2 instances 2 exposed
Issued
Jan 24, 2024
Abate by
Apr 19, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(4):Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  On or about October 8, 2023, a Unicarrier forklift was utilized with an 8ft forklift extension attachment without the manufacturer's prior written approval.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Novares US Engine Components INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347121360.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.