OSHA Inspection: NOVARES US ENGINE COMPONENTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NOVARES US ENGINE COMPONENTS, INC. in 2929 VENTURE DRIVE, JANESVILLE, WI 53546 (NAICS 326199). OSHA activity number 347231466.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Novares US Engine Components, INC. — free Get an email when a new federal OSHA severe-injury report for Novares US Engine Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2929 VENTURE DRIVE
City
JANESVILLE
State
WI
ZIP
53546
Mailing
2929 VENTURE DRIVE, JANESVILLE, WI 53546
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2024
Abate by
Aug 30, 2024
Penalty
Initial $11,524 · Current $6,914 Reduced
29 CFR  1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about January 23, 2024, the employer did not ensure that periodic inspections were being completed at least annually to ensure that the procedure remained accurate, and to correct any deficiencies found during the inspection.
Recent events (2)
  • — I (S) $6914.4
  • — Z (S) $11524

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2024
Abate by
Jul 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(B):The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  On or about January 23, 2024, the employer did not have an adequate hazardous energy control procedure for the Milacron MPS 725, (Machine 8826/SN- M6801AA020031), that required the employee completing the procedure to keep the key on their person, rather than having it tethered to the machine.