MADISON, SD —
OSHA Inspection: PPD (USA) INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PPD (USA) INC. in 1810 NORTHEAST 3RD STREET, MADISON, SD 57042 (NAICS 326112). OSHA activity number 347141129.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PPD (USA) INC.
- Site address
- 1810 NORTHEAST 3RD STREET
- City
- MADISON
- State
- SD
- ZIP
- 57042
- Mailing
- 1810 NORTHEAST 3RD STREET, MADISON, SD 57042
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 89
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A03 II
- Issued
- Mar 7, 2024
- Abate by
- Apr 2, 2024
- Penalty
- Initial $11,292 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded or guards were not designed and constructed to prevent employees from having any part of their body in the danger zone during operating cycle(s): (a) PPD (USA) Inc. at 1810 Northeast 3rd Street, Madison, SD 57042: On or about and at times prior to December 4, 2023, the employer did not ensure that the point of operation on the Numatics Bearing Press (Model: 153SA431K000030) was adequately guarded to prevent employees from having any part of their body in the danger zone during machine operations. Two-handed operation safety devices were installed in a manner that allowed for devices to be easily defeated. This hazard exposed employees to crushing and amputation hazards.
Recent events (2)
- — I (S) $8000
- — Z (S) $11292
1910.305 B03 II
- Issued
- Mar 7, 2024
- Abate by
- Apr 2, 2024
- Penalty
- Initial $4,839 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(3)(ii): Boxes were not closed by suitable covers securely fastened in place: (a)PPD (USA) Inc. at 1810 Northeast 3rd Street, Madison, SD 57042: On or about and at times prior to December 4, 2023, the employer did not ensure that damaged electrical equipment was repaired/replaced in that an outlet cover plate located in the finishing area was damaged such that live conductors were accessible. This condition exposed employees to shock and electrocution hazards.
Recent events (2)
- — I (O) $4000
- — Z (S) $4839
1910.305 G01 IV
- Issued
- Mar 7, 2024
- Abate by
- Apr 2, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv):Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a)PPD (USA) Inc. at 1810 Northeast 3rd Street, Madison, SD 57042: On or about and at times prior to December 4, 2023, the employer did not ensure that flexible extension cords and relocatable power taps were properly utilized in that extension cords and relocatable power taps were attached to building surfaces and machine surfaces via wrapping and using zip ties to create a permanent wiring configuration. This condition exposed employees to shock and electrocution hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Mar 7, 2024
- Abate by
- Apr 2, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a)PPD (USA) Inc. at 1810 Northeast 3rd Street, Madison, SD 57042: On or about and at times prior to December 4, 2023, the employer did not ensure that the periodic inspections of energy control procedures were conducted at least annually. This condition exposed employees to hazards associated with inadequate procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PPD (USA) INC.
View PPD (USA) INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347141129.