WEST CHESTER, OH —
OSHA Inspection: REPUBLIC WIRE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of REPUBLIC WIRE, INC. in 5525 UNION CENTER DRIVE, WEST CHESTER, OH 45069 (NAICS 332618). OSHA activity number 347148363.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REPUBLIC WIRE, INC.
- Site address
- 5525 UNION CENTER DRIVE
- City
- WEST CHESTER
- State
- OH
- ZIP
- 45069
- Mailing
- 5525 UNION CENTER DRIVE, WEST CHESTER, OH 45069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Feb 22, 2024
- Abate by
- Mar 26, 2024
- Penalty
- Initial $15,970 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) On or about 12/7/2023 the employer did not ensure that the employer's energy control program adequately addressed the following topics including energy control procedures, employee training and periodic inspections, in that the current program required employees to fill out a form on lockout versus providing a machine specific procedures for the employees performing servicing and maintenance on equipment such as but not limited to; Windak Auto Reeler Machine (AR24-D) to follow to ensure that through training the authorized employees understood the hazardous energy sources and the procedures to secure such hazardous energy sources; electric and pneumatics.
Recent events (2)
- — I (S) $5000
- — Z (S) $15970
1910.147 D
- Issued
- Feb 22, 2024
- Abate by
- Mar 26, 2024
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy. (2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. (3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (4) Lockout or tagout device application. (4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. (4)(ii) Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a "safe" or "off" position. (5) Stored energy. (5)(i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. (5)(ii) If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists. (6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished. a) On or about 12/1/2023 the employer did not ensure that (d)(1) through (d)(6) were followed by each authorized employee performing servicing and maintenance on equipment such as Windak Auto Reeler Machine (AR24-D), located on the reeling line. An authorized employee did not properly secure the electrical disconnect and pneumatics power to the lift table. exposing each employee to the caught in hazard of the lift tables, during servicing operations.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
More inspections at Republic Wire, INC.
View Republic Wire, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347148363.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.