OSHA Inspection: DARCON CONSTRUCTION INC

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of DARCON CONSTRUCTION INC in 1095 SOUTHERN BLVD, BRONX, NY 10459 (NAICS 238110). OSHA activity number 347162133.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Darcon Construction INC — free Get an email when a new federal OSHA severe-injury report for Darcon Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
1095 SOUTHERN BLVD
City
BRONX
State
NY
ZIP
10459
Mailing
360 MEACHAM AVE, ELMONT, NY 11003
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.134 C01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Mar 18, 2024
Penalty
Initial $4,839 · Current $3,500 Reduced
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   Location: 1095 Southern Blvd, Bronx, NY  a) On or about October 26, 2023, the employer did not establish and implement a written respiratory protection program for employees who were required to wear an N95 respirator while cutting steel support of excavation (SOE) beams using an acetylene torch.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $4839

1910.134 E01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Mar 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   Location: 1095 Southern Blvd, Bronx, NY  a) On or about October 26, 2023, the employer did not medically evaluate employees who were required wear an N95 respirator when while cutting steel support of excavation beams using an acetylene torch.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 F01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Mar 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  Location: 1095 Southern Blvd, Bronx, NY  a) On or about October 26, 2023, the employer did not ensure that employee(s) passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) prior to wearing an N95 respirator while cutting steel support of excavation beams using an acetylene torch.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Darcon Construction INC's full OSHA safety record →