OSHA Inspection: EUROFORGROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EUROFORGROUP in 99 TROY HAWK RUN HIGHWAY, PHILIPSBURG, PA 16866 (NAICS 333132). OSHA activity number 347184988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Euroforgroup — free Get an email when a new federal OSHA severe-injury report for Euroforgroup is published. One employer, no account, unsubscribe in one click.
Establishment
EUROFORGROUP
Site address
99 TROY HAWK RUN HIGHWAY
City
PHILIPSBURG
State
PA
ZIP
16866
Mailing
99 TROY HAWK RUN HIGHWAY, PHILIPSBURG, PA 16866
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
41
Ownership type
A

4 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 30 exposed
Issued
Mar 14, 2024
Abate by
Apr 9, 2024
Penalty
Initial $8,228 · Current $3,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a.)  Euroforgroup dba Reichdrill, LLC; gas storage trailer -  On or about 1/4/24, and times prior thereto,  oxygen and acetylene, propylene,  and propane cylinders were stored within less than 8 feet of each other without a 1/2 hour fire rated barrier.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $8228

1910.303 G01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 14, 2024
Penalty
Initial $3,496 · Current $3,000 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a.)  Euroforgroup dba Reichdrill, LLC, electrical assembly area - On or about 1/4/24, and times prior thereto, items including, but not limited to, cardboard boxes, and miscellaneous spools of wire were stored within 6 inches of the front of the electrical panel boxes.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3496

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Mar 14, 2024
Abate by
Apr 9, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a.) Eurogroup dba Reichdrill, LLC, electric assembly room - On or about 1/4/2024, and at times prior thereto, one class ABC fire extinguisher was not mounted.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B01 II

Other-than-serious 1 instance 30 exposed
Issued
Mar 14, 2024
Abate by
Apr 9, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(1)(ii): The marking on compressed gas cylinders identifying the content with either the chemical or trade name of the gas was not marked by means of stenciling, stamping, or labeling, and could be readily removed:    a.)  Euroforgroup dba Reichdrill, LLC; northwest exit door/plasma cutter -  On or about 1/4/24, and times prior thereto,  one propane cylinders was being used without markings to indicate what was in the compressed gas cylinder.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Euroforgroup's full OSHA safety record →