STRONGSVILLE, OH —
OSHA Inspection: BRILLIANT ELECTRIC SIGN CO., LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRILLIANT ELECTRIC SIGN CO., LTD. in 16761 SOUTHPARK CENTER, STRONGSVILLE, OH 44136 (NAICS 339950). OSHA activity number 347192007.
Where did this inspection happen?
- Establishment
- BRILLIANT ELECTRIC SIGN CO., LTD.
- Site address
- 16761 SOUTHPARK CENTER
- City
- STRONGSVILLE
- State
- OH
- ZIP
- 44136
- Mailing
- 4811 VAN EPPS RD., CLEVELAND, OH 44131
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 37
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.27 A
- Issued
- Penalty
- Initial $6857.00 · Current $3428.00 Reduced
General-duty citation text
29 CFR 1910.27(a): The employer did not ensure that scaffolds used in general industry met the requirements in 29 CFR part 1926, subpart L (Scaffolds) in the following instances. (a) 1926.451(b)(1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports. On or about January 03, 2024, during an electrical sign repair project on a commercial building located at 16761 SouthPark Center, Strongsville, OH 44136, The employer did not ensure that each platform on all working levels of the supported scaffolding were fully planked and/or decked, exposing an employee to fall hazards. (b) 1926.451(f)(3): Scaffolds and scaffold components were not inspected by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On or about January 03, 2024, , during an electrical sign repair project on a commercial building located at 16761 SouthPark Center, Strongsville, OH 44136, the employer did not ensure that the supported scaffolding was inspected prior to use, exposing employees to fall hazards due to deficiencies in the construction and installation of the scaffold. (c) 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about January 03, 2024, during an electrical sign repair project on a commercial building located at 16761 SouthPark Center, Strongsville, OH 44136, the employer did not ensure an employee working from a supported scaffold was protected from a fall of approximately (greater than 15 feet) by the use of a personal fall arrest system or guardrail system.
Recent events (2)
- — I (S) $3428
- — Z (S) $6857
More inspections at BRILLIANT ELECTRIC SIGN CO., LTD.
DOVER, OH—2022-03-03 00:00:00
BRILLIANT ELECTRIC SIGN CO., LTD.
CLEVELAND, OH—2011-11-29 00:00:00
BRILLIANT ELECTRIC SIGN CO., LTD.
View BRILLIANT ELECTRIC SIGN CO., LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 339950)
KINGS MOUNTAIN, NC—2026-07-09 00:00:00
161533 - DIRECT WHOLESALE SIGNS LLC
APEX, NC—2026-07-07 00:00:00
161498 - SEVEN SPRINGS, INC.
MINNEAPOLIS, MN—2026-06-30 00:00:00
111500 - SIGNMINDS INC
ANGIER, NC—2026-06-29 00:00:00
161462 - CAROLINA SIGN AND SERVICE, LLC
GREENE, NY—2026-06-17 00:00:00
RAPP SIGNS, INC.
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347192007.