Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEMAK USA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NEMAK USA, INC. in 4243 GATEWAY DRIVE, SHEBOYGAN, WI 53081 (NAICS 331523). OSHA activity number 347206559.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nemak USA, INC. — free Get an email when a new federal OSHA severe-injury report for Nemak USA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NEMAK USA, INC.
Site address
4243 GATEWAY DRIVE
City
SHEBOYGAN
State
WI
ZIP
53081
Mailing
4243 GATEWAY DRIVE, SHEBOYGAN, WI 53081
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331523
Employees
852
Ownership type
A

2 citations on file for this inspection.

1910.219 E02 I

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 7, 2024
Penalty
Initial $13,711 · Current $10,000 Reduced
29 CFR 1910.219(e)(2)(i): Overhead horizontal belts, with lower parts seven (7) feet or less from the floor or platform, shall be guarded on sides and bottom in accordance with paragraph (o)(3) of this section.  On or about January 10, 2024, at the facility located at 4243 Gateway Drive, Sheboygan, Wisconsin; the employer failed to ensure horizontal belts lower than seven feet from the floor were properly guarded.  Specifically, the guard did not fully enclose the bottom run of the south discharge conveyor drive belt on Bag House #14.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13711

1910.147 D

Deleted Serious Gravity 10 1 instance 9 exposed
Issued
Jun 7, 2024
Abate by
Jul 9, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about January 10, 2024, at the facility located at 4243 Gateway Drive, Sheboygan, Wisconsin; employees were exposed to machine hazards associated with moving parts when they engaged in troubleshooting the Bag House #14 south discharge conveyor.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to lift up the south discharge conveyor drive belt guard.  The machine was not deenergized prior to employees engaging in the servicing / maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Nemak USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347206559.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.