MIDLAND, TX —
OSHA Inspection: PSI OILFIELD SERVICES, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PSI OILFIELD SERVICES, LLC. in 9413 EAST COUNTY ROAD 97, MIDLAND, TX 79706 (NAICS 213112). OSHA activity number 347220964.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PSI OILFIELD SERVICES, LLC.
- Site address
- 9413 EAST COUNTY ROAD 97
- City
- MIDLAND
- State
- TX
- ZIP
- 79706
- Mailing
- PO BOX 53138, MIDLAND, TX 79710
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 C06
- Issued
- Jun 24, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $5,531 · Current $1,659 Reduced
General-duty citation text
29 CFR 1910.107(c)(6):Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations. On or about January 17, 2024,and times prior thereto, in the spray paint coating area, the employer did not ensure use of explosion-proof industrial fan and outlets that were withing twenty (20) feet of active spraying, as employees coated metal parts for the oil and gas field.
Recent events (2)
- — I (O) $1659.3
- — Z (S) $5531
1910.184 C01
- Issued
- Jun 24, 2024
- Penalty
- Initial $3,687 · Current $1,106 Reduced
General-duty citation text
29 CFR 1910.184(c)(1):Slings that are damaged or defective shall not be used. On or about January 17, 2024, at the main bay are on crane, the employer did not remove from service worn and frayed synthetic slings used to move piping. The sling was not inspected for damage or defects by the employer prior to use.
Recent events (2)
- — I (O) $1106.1
- — Z (S) $3687
1910.303 B07 I
- Issued
- Jun 24, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $4,610 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about January 17, 2024, in the spray paint coating area behind PPE cabinet, the employer failed to ensure that an electrical switch box was enclosed to ensure that live electrical components were safeguarded, while employees painted parts.
Recent events (2)
- — I (O) $0
- — Z (S) $4610
1910.157 C01
- Issued
- Jun 24, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $518 · Current $155 Reduced
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about January 17, 2024, in the main bay was placed in the base of a structural I beam close to the ground, the employer failed to mount the fire extinguisher in a location accessible to all employees, where employees grind and weld metal.
Recent events (2)
- — I (O) $155.4
- — Z (O) $518
1910.157 C04
- Issued
- Jun 24, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: On or about January 17, 2024, at the main bay area near bay doors, the employer did not conduct frequent and regular inspections to identify and correct hazards such as but not limited to inspecting the charge on fire extinguishers, where employees grind and weld metal.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Jun 24, 2024
- Abate by
- Aug 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Hose used in lieu of Class A portable fire extinguishers were not visually inspected at least monthly: On or about January 17, 024, the main bay area, the employer did not ensure portable fire extinguisher(s) were not visually inspected at least monthly, where employees grind and weld metal.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PSI Oilfield Services, LLC.