Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AK BUILDERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AK BUILDERS, LLC in LOT 16 HAWTHORNE DRIVE, HARRISBURG, PA 17110 (NAICS 238130). OSHA activity number 347226839.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AK Builders, LLC — free Get an email when a new federal OSHA severe-injury report for AK Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AK BUILDERS, LLC
Site address
LOT 16 HAWTHORNE DRIVE
City
HARRISBURG
State
PA
ZIP
17110
Mailing
507 MAY POST OFFICE ROAD, STRASBURG, PA 17579
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 4, 2024
Abate by
Jul 1, 2024
Penalty
Initial $6,452 · Current $6,452
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  a) Lot 16, Hawthorne Drive, Harrisburg, PA 17110, unfinished stairway landing between the first and second floors, on or about January 23, 2024, employees were exposed to a fall hazard of approximately 7-feet through an exterior wall opening to the ground below.  The wall opening was not equipped with a top rail, and personal fall arrest systems were not in use.  b) Lot 16, Hawthorne Drive, Harrisburg, PA 17110, second floor, on or about January 23, 2024, employees were exposed to a fall hazard of approximately 10-feet through exterior wall openings to the ground below.  The wall openings was not equipped with a top rails, and personal fall arrest systems were not in use.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $6452

1926.503 C

Serious Gravity 10 2 instances 2 exposed
Issued
Jun 4, 2024
Abate by
Jul 8, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.503(c):  The employer did not retrain affected employees who already had been trained but demonstrated inadequate understanding and skill required by paragraph (a) of this section:  a) Lot 16, Hawthorne Drive, Harrisburg, PA 17110 - Employees were exposed to fall hazards from improperly guarded window openings, and a failure to utilize personal fall arrest systems.  Employees were previously trained on fall protection but did not understand the fall protection requirements for residential construction.  b) Lot 16, Hawthorne Drive, Harrisburg, PA 17110 - Employees were exposed to fall hazards from improperly guarded window openings.  Employees were previously trained on fall protection but did not understand the guardrail system requirements.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 4, 2024
Abate by
Jul 1, 2024
Penalty
Initial $3,687 · Current $3,687
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed.  a) Lot 16, Hawthorne Drive, Harrisburg, PA 17110 - On or about January 23, 2024, employees were accessing a stairway landing of the residential structure by way of a 6-foot Werner, fiberglass, folding stepladder that was in the folded position and set on unstable plywood.  The ladder was not being used for the purpose for which it was designed by the manufacturer.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3687

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 4, 2024
Abate by
Jul 1, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1):  Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.  a) Lot 16, Hawthorne Drive, Harrisburg, PA 17110 - On or about January 23, 2024, employees were using a 6-foot Werner, fiberglass, folding stepladder to access the landing surface of an unfinished stairwell, and the ladder only extended approximately one-foot above the landing surface.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.502 I04

Other-than-serious 1 instance 2 exposed
Issued
Jun 4, 2024
Abate by
Jul 1, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard.  a) Lot 16, Hawthorne Drive, Harrisburg, PA 17110 - Employees were accessing a stairway landing of the residential structure by way of a 6-ft Werner folding ladder that was set on top of plywood covering the basement stair access hole, and the covering was not color-coded or marked with the word "HOLE" or "COVER".    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0

View AK Builders, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347226839.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.