NORMAL, IL —
OSHA Inspection: R.B. WHITE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of R.B. WHITE, INC. in 2002 EAGLE RD., NORMAL, IL 61761 (NAICS 337215). OSHA activity number 347229163.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.B. WHITE, INC.
- Site address
- 2002 EAGLE RD.
- City
- NORMAL
- State
- IL
- ZIP
- 61761
- Mailing
- 2002 EAGLE RD. ATTN: ROB FOGLER, NORMAL, IL 61761
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- Employees
- 47
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 16, 2024
- Abate by
- Jun 17, 2024
- Penalty
- Initial $11,292 · Current $11,292
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about January 22, 2024, an employee performing service and maintenance activities on the wire straightening machine was exposed to an amputation hazard and the employer's machine specific procedures did not include the techniques to be used to address all the energy sources associated with the equipment.
Recent events (1)
- — Z (S) $11292
1910.147 D
- Issued
- May 16, 2024
- Abate by
- Jun 10, 2024
- Penalty
- Initial $11,292 · Current $11,292
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about January 22, 2024, an employee was exposed to machine hazards associated with moving parts, while clearing a broken wire, from the of the Shuster-Mettler Automatic Wire Straightening and Cutting Machine. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], was not implemented to protect employees from machine servicing hazards.
Recent events (1)
- — Z (S) $11292
More inspections at R.B. White, INC.