OSHA Inspection: A & A COATING INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A & A COATING INC. in 3679 FM 250, LONE STAR, TX 75668 (NAICS 333318). OSHA activity number 347275372.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & a Coating INC. — free Get an email when a new federal OSHA severe-injury report for A & a Coating INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A & A COATING INC.
Site address
3679 FM 250
City
LONE STAR
State
TX
ZIP
75668
Mailing
3679 FM 250, LONE STAR, TX 75668
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333318
Employees
51
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 19, 2024
Abate by
Aug 14, 2024
Penalty
Initial $11,292 · Current $4,517 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about February 8, 2024 and times prior employees were exposed to unguarded rotating part machine hazards while working on BTF line in plant #1.
Recent events (2)
  • — I (S) $4516.8
  • — Z (S) $11292

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2024
Penalty
Initial $6,453 · Current $2,581 Reduced
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about February 8, and times prior to, employees utilizing break room in BTF plant #1 were exposed to electrical hazards from a uncovered light switch box and junction box, energizing an overhead light of the room.