Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURATE CONVERTER RECYCLING, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ACCURATE CONVERTER RECYCLING, LLC in 133 MAPLE STREET, STOUGHTON, MA 02072 (NAICS 423930). OSHA activity number 347289514.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate Converter Recycling, LLC — free Get an email when a new federal OSHA severe-injury report for Accurate Converter Recycling, LLC is published. One employer, no account, unsubscribe in one click.
Site address
133 MAPLE STREET
City
STOUGHTON
State
MA
ZIP
02072
Mailing
133 MAPLE STREET, STOUGHTON, MA 02072
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 4 instances 6 exposed
Issued
May 14, 2024
Abate by
Aug 5, 2024
Penalty
Initial $3,687 · Current $1,000 Reduced

Hazardous substances 81108111

29 CFR  1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  A) On or about February 29, 2024, in the machine room at Accurate Converter Recycling LLC on 133 Maple Street Suite 2, Stoughton, MA 02072,  an employee was exposed to  an 8-hour time weighted average noise level of 96.7 dBA (equivalently a dose of 253 %) in excess of the 85 dBA (equivalently a dose of 50%) while operating the catalytic converter cutting machine where a hearing conservation program had not been implemented. B)On or about February 29, 2024, in the machine room at Accurate Converter Recycling LLC on 133 Maple Street Suite 2, Stoughton, MA 02072,  an employee was exposed to  an 8-hour time weighted average noise level of 95.7 dBA (equivalently a dose of 221.6 %) in excess of the 85 dBA (equivalently a dose of 50%) while operating the catalytic converter cutting machine where a hearing conservation program had not been implemented. C) On or about February 29, 2024, in the machine room at Accurate Converter Recycling LLC on 133 Maple Street Suite 2, Stoughton, MA 02072,  an employee was exposed to  an 8-hour time weighted average noise level of 95.6 dBA (equivalently a dose of 216.5 %) in excess of the 85 dBA (equivalently a dose of 50%) while operating the catalytic converter cutting machine where a hearing conservation program had not been implemented. D) On or about February 29, 2024, in the machine room at Accurate Converter Recycling LLC on 133 Maple Street Suite 2, Stoughton, MA 02072,  an employee was exposed to  an 8-hour time weighted average noise level of 95.9 dBA (equivalently a dose of 225.8 %) in excess of the 85 dBA (equivalently a dose of 50%) while operating the catalytic converter cutting machine where a hearing conservation program had not been implemented.  The hearing conservation shall include monitoring, offering hearing, baseline & annual audiometric testing, noise training, and posting of standard 29 CFR 1910.95.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3687

1910.134 C01

Serious Gravity 1 1 instance 4 exposed
Issued
May 14, 2024
Penalty
Initial $2,765 · Current $1,000 Reduced

Hazardous substances 01600685258790009130

29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   On or about February 16, 2024, in the machine room at Accurate Converter Recycling LLC on 133 Maple Street Suite 2, Stoughton, MA 02072, employees were required to wear 3M Powered Air Purifying Respirators where employer did not establish or implement a written respiratory program that included: (ii) Medical evaluations of employees required to use respirators, (v) Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators, and (ix) Procedures for regularly evaluating the effectiveness of the program.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2765

View Accurate Converter Recycling, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347289514.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.