STOUGHTON, MA —
OSHA Inspection: ACCURATE CONVERTER RECYCLING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACCURATE CONVERTER RECYCLING, LLC in 133 MAPLE STREET, STOUGHTON, MA 02072 (NAICS 423930). OSHA activity number 347290041.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURATE CONVERTER RECYCLING, LLC
- Site address
- 133 MAPLE STREET
- City
- STOUGHTON
- State
- MA
- ZIP
- 02072
- Mailing
- 133 MAPLE STREET, STOUGHTON, MA 02072
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 14, 2024
- Abate by
- Jul 5, 2024
- Penalty
- Initial $3,687 · Current $1,843 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Location: Accurate Converter Cutting Machine, 133 Maple St, Stoughton, MA On or about February 16, 2024, employees were exposed to uncontrolled energy when clearing jams on the catalytic converter cutting machine where procedures were not developed, documented and utilized for the control of potentially hazardous energy.
Recent events (2)
- — I (S) $1843
- — Z (S) $3687
1910.212 A03 II
- Issued
- May 14, 2024
- Abate by
- Jul 5, 2024
- Penalty
- Initial $6,452 · Current $3,226 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Location: Accurate Converter Cutting Machine, 133 Maple St, Stoughton, MA On or about February 16, 2024, employees were exposed to crushing and amputation hazards when operating a cutting machine that was not guarded to prevent arms, hands, and fingers from contacting the blade or crushing apparatus.
Recent events (2)
- — I (S) $3226
- — Z (S) $6452
1904.40 A
- Issued
- May 14, 2024
- Penalty
- Initial $922 · Current $431 Reduced
General-duty citation text
29 CFR 1904.40(a):The employer did not provide an authorized government representative the records within the four business hours. Location: Worksite On or about February 16, 2024, the employer failed to provide copies of the injury and illness records to an authorized representative with the required time.
Recent events (2)
- — I (O) $431
- — Z (O) $922
More inspections at Accurate Converter Recycling, LLC
View Accurate Converter Recycling, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347290041.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.