PELHAM, NH —
OSHA Inspection: UPNOVR, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of UPNOVR, INC. in 31 PULPIT ROCK ROAD, PELHAM, NH 03076 (NAICS 332999). OSHA activity number 347298424.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UPNOVR, INC.
- Site address
- 31 PULPIT ROCK ROAD
- City
- PELHAM
- State
- NH
- ZIP
- 03076
- Mailing
- P.O. BOX 199, PELHAM, NH 03076
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 C01
- Issued
- Apr 12, 2024
- Abate by
- Jul 1, 2024
- Penalty
- Initial $2,074 · Current $1,037 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Location: Filling Room On or about February 22, 2024, the employer did not establish and implement a written respiratory protection program for employees required to wear a half face elastomeric respirator when exposed to respiratory hazards during the mixing of stair tread filler.
Recent events (2)
- — I (S) $1037
- — Z (S) $2074
1910.134 E01
- Issued
- Apr 12, 2024
- Abate by
- Jul 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Location: Filling Room On or about February 22, 2024, employees required to wear half face elastomeric respirators were not medically evaluated by the employer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Apr 12, 2024
- Abate by
- Jul 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Location: Filling Room On or about February 22, 2024, employees required to wear respirators were not fit tested by the employer prior to wearing a half face elastomeric respirator when exposed to respiratory hazards during the mixing of stair tread filler.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Apr 12, 2024
- Abate by
- Jul 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: Location: Filling Room On or about February 22, 2024, employees were exposed to respiratory and dermal irritation when they wore a half face elastomeric respirator that had been stored unprotected from contamination hanging in the work area visibly coated in dust.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Apr 12, 2024
- Abate by
- Jul 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: Location: Filling Room On or about February 22, 2024, the employer did not provide training to employees required to wear a half face elastomeric respirator when exposed to respiratory hazards during the mixing of stair tread filler.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Upnovr, INC.
View Upnovr, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347298424.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.