MECHANICSBURG, PA —
OSHA Inspection: AQUA TREATMENT SERVICES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AQUA TREATMENT SERVICES, INC. in 194 HEMPT ROAD, MECHANICSBURG, PA 17050 (NAICS 333318). OSHA activity number 347318776.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AQUA TREATMENT SERVICES, INC.
- Site address
- 194 HEMPT ROAD
- City
- MECHANICSBURG
- State
- PA
- ZIP
- 17050
- Mailing
- 194 HEMPT ROAD, MECHANICSBURG, PA 17050
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333318
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.101 B
- Issued
- Jul 24, 2024
- Penalty
- Initial $6,453 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6. a) 194 Hempt Road Mechanicsburg PA 17050, Outer Building - On or about March 4, 2024, the employer was storing acetylene cylinders that were not secured from tipping over. b) 194 Hempt Road Mechanicsburg PA 17050, Outer Building - On or about March 4, 2024, the employer was storing a mixed assortment of empty and full acetylene cylinders. No abatement certification required.
Recent events (2)
- — I (S) $3000
- — Z (S) $6453
1910.134 E01
- Issued
- Jul 24, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $6,453 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. a) 194 Hempt Road, Mechanicsburg, PA 17050 , Outer Building - On or about March 4, 2024, an employee was wearing a 3M 6800 Full Face Air Purifying Respirator during the powder coating process and was not medically evaluated prior to using the respirator. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $6453
1910.134 F02
- Issued
- Jul 24, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) 194 Hempt Road, Mechanicsburg, PA 17050 , Outer Building - On or about March 4, 2024, employees were wearing 3M 6800 Full Face Air Purifying Respirators during the powder coating process and were not fit tested. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 D01
- Issued
- Jul 24, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $9,680 · Current $5,304 Reduced
0689
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI). a) 94 Hempt Road, Mechanicsburg, PA 17050 , Outer Building - on or about March 28, 2024, employees were conducting welding operations on stainless steel metal and the employer had not determined the 8-hour time-weighted average exposures for each employee. b) 194 Hempt Road, Mechanicsburg, PA 17050, Main Building - on or about April 3, 2024, employees were conducting welding operations on stainless steel metal and the employer had not determined the 8-hour time-weighted average exposures for each employee. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5304
- — Z (S) $9680
1910.1200 H01
- Issued
- Jul 24, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. a) 194 Hempt Road Mechanicsburg PA 17050, Outer Building - on or about March 4, 2024, employees were conducting welding operations on stainless product and were exposed to chemicals including but not limited to Hexavalent Chromium. The employer had not provided effective information or training to employees exposed to hazardous chemicals. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Jul 24, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible. a) 94 Hempt Road, Mechanicsburg, PA 17050 , Outer Building - on or about March 4, 2024, employees wore the NIOSH N99 Moldex #2310 during welding as a voluntary respirator, and were not provided with information contained in Appendix D. b) 94 Hempt Road, Mechanicsburg, PA 17050 , Outer Building - on or about March 4, 2024, employees wore the 3M Aura N95 #9211+ during sand blasting as a voluntary respirator, and were not provided with information contained in Appendix D. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Aqua Treatment Services, INC.
View Aqua Treatment Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333318)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347318776.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.