Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARRICK CONSTRUCTION, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GARRICK CONSTRUCTION, INC in 110 EAMES STREET, WILMINGTON, MA 01887 (NAICS 561730). OSHA activity number 347341869.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garrick Construction, INC — free Get an email when a new federal OSHA severe-injury report for Garrick Construction, INC is published. One employer, no account, unsubscribe in one click.
Site address
110 EAMES STREET
City
WILMINGTON
State
MA
ZIP
01887
Mailing
110 EAMES STREET, WILMINGTON, MA 01887
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
6
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2024
Abate by
Aug 16, 2024
Penalty
Initial $4,610 · Current $2,300 Reduced
OSH ACT of 1970 Section (5)(a)(1) - The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to tip overs:  Location - Facility Storage Bays / Equipment  On or about 3/13/2024, employees were exposed to ejection and crushing hazards while operating a powered industrial truck onsite without a seatbelt ( MFG - Clark / Model - CMP230L / Serial No. - 04816872KF).
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4610

1910.178 A06

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 1, 2024
Abate by
Aug 16, 2024
Penalty
Initial $4,610 · Current $0 Reduced
29 CFR 1910.178(a)(6) - The employer did not ensure that all nameplates or markings were maintained in a legible condition:  Location - Facility Storage Bays / Equipment Yard  On or about 3/13/2024, the nameplate with load capacities and identifying information for a powered industrial truck in service were found to be illegible.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4610

1910.178 Q01

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 1, 2024
Abate by
Aug 16, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(1) - Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  Location - Facility Storage Bays / Equipment Yard  On or about 3/13/2024, a powered industrial truck with unserviceable tires was not taken out of service as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 1, 2024
Abate by
Aug 16, 2024
Penalty
Initial $4,610 · Current $2,700 Reduced
29 CFR 1910.28(b)(1)(i) - Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):   Location - Facility Storage Bay  On or about 3/13/2024, employees were exposed to falling hazards in excess of four feet while accessing the top level of a shelving unit without fall protection.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4610

1910.253 B02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 1, 2024
Abate by
Jul 26, 2024
Penalty
Initial $4,610 · Current $2,000 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  Location - Facility Storage Bay  On or about 3/13/2024, a compressed gas cylinder containing an Argon/Carbon dioxide mixture was in danger of being knocked over and damaged as it was not securely stored.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4610

1910.253 B04 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 1, 2024
Abate by
Jul 26, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii) - Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  Location - Facility Storage Bay  On or about 3/13/2024, oxygen cylinders were stored in close proximity to an acetylene (fuel gas) cylinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Jul 1, 2024
Abate by
Jul 26, 2024
Penalty
Initial $518 · Current $200 Reduced
29 CFR 1910.178(l)(6) - The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  Location - Facility Storage Bays / Equipment Yard  On or about 3/13/2024, an employee had not been certified to operate powered industrial trucks by the employer as required.
Recent events (2)
  • — I (O) $200
  • — Z (O) $518

1910.303 G01

Other-than-serious 1 instance 6 exposed
Issued
Jul 1, 2024
Abate by
Jul 26, 2024
Penalty
Initial $518 · Current $0 Reduced
29 CFR 1910.303(g)(1) - Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Location - Facility Storage Bay  On or about 3/13/2024, a live electrical panel were obstructed by various items including buckets of material, and a filled garbage can.
Recent events (2)
  • — I (O) $0
  • — Z (O) $518

View Garrick Construction, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347341869.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.