Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT. OF ARMY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. DEPT. OF ARMY in FORT LIBERTY, FORT LIBERTY, NC 28310 (NAICS 928110). OSHA activity number 347352528.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Army — free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Army is published. One employer, no account, unsubscribe in one click.
Establishment
U.S. DEPT. OF ARMY
Site address
FORT LIBERTY
City
FORT LIBERTY
State
NC
ZIP
28310
Mailing
FORT LIBERTY, FORT LIBERTY, NC 28310
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
75
Ownership type
D

3 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.22(a)(1):All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  The employer did not ensure that all passageways were kept clean and orderly. A flexible extension cord was laying across walking paths, exposing employees to tripping hazards.
Recent events (1)
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(1):Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:  Extension cord outer insulation was frayed,  exposing employees to live energized conductors.
Recent events (1)
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 8, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(j)(2)(iv):A receptacle installed in a wet or damp location shall be suitable for the location.  120v receptacle outlet was installed next to the building water source and was not designed for wet or damp locations.