CHICAGO, IL —
OSHA Inspection: MONDELEZ GLOBAL, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MONDELEZ GLOBAL, LLC in 7300 S. KEDZIE AVENUE, CHICAGO, IL 60629 (NAICS 311821). OSHA activity number 347360463.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONDELEZ GLOBAL, LLC
- Site address
- 7300 S. KEDZIE AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60629
- Mailing
- 7300 S. KEDZIE AVENUE, CHICAGO, IL 60629
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311821
- Employees
- 672
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C06 I
- Issued
- Jun 13, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $11,524 · Current $5,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) 38th Parallel - On or about February 3, 2024, and dates prior to, sanitation employees performed servicing and/or maintenance by cleaning the intermediate exhauster for system 2. However, the employer did not ensure periodic inspections of the energy control procedures were performed at least annually with authorized employees. b.) 38th Parallel - On or about February 27, 2024, and dates prior to, an electrician performed service and/or maintenance by locking out the electrical panel for the system 1 intermediate exhauster. However, the employer did not ensure periodic inspections of the energy control procedures were performed at least annually with authorized employees.
Recent events (2)
- — I (S) $5800
- — Z (S) $11524
More inspections at Mondelez Global, LLC
View Mondelez Global, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311821)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347360463.