Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AN-COR INDUSTRIAL PLASTICS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AN-COR INDUSTRIAL PLASTICS, INC. in 900 NIAGARA FALLS BLVD, NORTH TONAWANDA, NY 14120 (NAICS 325211). OSHA activity number 347363632.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch An-Cor Industrial Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for An-Cor Industrial Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
900 NIAGARA FALLS BLVD
City
NORTH TONAWANDA
State
NY
ZIP
14120
Mailing
900 NIAGARA FALLS BLVD, NORTH TONAWANDA, NY 14120
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
325211
Employees
50
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 2 instances 30 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $8,067 · Current $4,000 Reduced
29 CFR 1910.22(a)(1): Place(s) of employment were not kept clean  a) On or about 03/21/2024, the Grinding Area, where employees grind fiberglass vessels contained a hazardous accumulation of combustible dust such as resin and fiberglass dust along floors, walls, surfaces, roof structures, dust booths, and electrical installations exposing employees to fire and explosion hazards.  b) On or about 03/21/2024, the CNC Room, where employees use the CNC router contained a hazardous accumulation of combustible dust such as wood dust along floors, walls, surfaces, and electrical installations exposing employees to fire and explosion hazards.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $4000
  • — Z (S) $8067

1910.307 C

Deleted Serious Gravity 5 2 instances 50 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $0 · Current $0

Hazardous substances E200

29 CFR  1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  a) On or about 03/21/2024, On the Production floor, combustible dust from fiberglass and resin was accumulating on surfaces while intrinsically unsafe electrical wiring, outlets with faceplates unprotected lighting, and non-dustproof equipment were utilized, exposing employees to fire and explosion hazards.  b)  On or about 03/21/2024, in the CNC room, combustible dust from wood was accumulating on surfaces while intrinsically unsafe electrical wiring, and non-dust proof equipment were utilized, exposing employees to fire and explosion hazards.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 II B 2

Serious Gravity 5 2 instances 30 exposed
Issued
Jul 16, 2024
Abate by
Jun 2, 2025
Penalty
Initial $8,067 · Current $4,000 Reduced
29 CFR  1910.106(e)(2)(ii)(b)(2): The quantity of Category 2, 3 or 4 flammable liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons:  a) On or about 03/21/2024; in the Mixing Room; employees are exposed to fire hazards when the quantity of Category 2 and 3 flammable, such as but not limited to epoxy vinyl ester resin, Cobalt 6% and Acetone, located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building, was approximately 330 gallons.  b) On or about 03/21/2024; in walkway by the PCX  area; employees are exposed to fire hazards when the quantity of Category 2 and 3 flammable, such as but not limited to epoxy vinyl ester resin, Hetron 197-3 resin, and Hetron 800 resin, located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building, was approximately 990 gallons.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $4000
  • — Z (S) $8067

1910.106 E06 II

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $6,453 · Current $3,500 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), were dispensed into containers without the nozzle and container being electrically interconnected.  a) On or about 03/21/2024, in the Acetone stations throughout the production area, when employees dispose of the Acetone from their small container to the 55-gallon drum, employees did not use bonding wires to electrically interconnect the drums and containers together, exposing employees to fire hazards.   b) On or about 03/21/2024, in the mixing room, when employees mixed flammable liquids such as resins (styrene) and catalysts (Cobalt, MEKP)  in 55-gallon drums, employees did not use bonding wires to electrically interconnect the containers or the mixer together exposing employees to fire hazards.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6453

1910.106 E06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  a) On or about 03/21/2024, in the mixing room, when employees mixed flammable liquids such as resins (styrene) and catalysts (Cobalt, MEKP)  in 55-gallon drums, employees did not ground the drum to remove static electricity, exposing employees to fire hazards.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 16, 2024
Penalty
Initial $6,857 · Current $3,500 Reduced
29 CFR  1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:  a) On or about 03/21/2024, in the Grinding Area, when employees operate the table saw to cut fiberglass products, employees are exposed to amputation hazards due to the blade being exposed.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6857

1910.243 C04

Deleted Serious Gravity 1 1 instance 7 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR  1910.243(c)(4):The angular exposure on the grinding wheel periphery and sides for safety guard(s) used on portable grinding machine(s) exceeded 180 degrees:  a) On or about 03/21/2024, in the grinding area, when employees grind fiberglass products they use DeWALT angle grinders that do not have the guards attached, exposing employees to laceration hazards.  ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

1910.157 G03

Other-than-serious 1 instance 3 exposed
Issued
Jul 16, 2024
Abate by
Aug 9, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(g)(3): Employees who have been designated to use fire fighting equipment as part of the emergency action plan were not provided training in the use of the appropriate equipment:  a) On 03/21/2024, throughout the establishment, employees who were designated to use fire extinguishers in the event of a fire were not provided hands-on practical training on the use of fire extinguishers.   ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View An-Cor Industrial Plastics, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347363632.