OSHA Inspection: U. S. DEPARTMENT OF AGRICULTURE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U. S. DEPARTMENT OF AGRICULTURE in 215 THIRD LOOP ROAD SUITE 100, FLORENCE, SC 29505 (NAICS 926140). OSHA activity number 347367401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U. S. Department of Agriculture — free Get an email when a new federal OSHA severe-injury report for U. S. Department of Agriculture is published. One employer, no account, unsubscribe in one click.
Site address
215 THIRD LOOP ROAD SUITE 100
City
FLORENCE
State
SC
ZIP
29505
Mailing
215 THIRD LOOP ROAD SUITE 100, FLORENCE, SC 29505
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
926140
Employees
6
Ownership type
D

1 citation on file for this inspection.

1910.303 B02

Serious Gravity 1 3 instances 3 exposed
Issued
May 28, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)	West end of the office. Inside of an employee's cubicle:  A 120-volt ISOBAR Relocatable Power Tap was daisy chained into another 120-volt ISOBAR Relocatable Power Tap to provide power to the cubicle.   b) West end of the office. Inside of an employee's cubicle: An ISOBAR Relocatable Power Tap designed and listed for a high concentration of low powered loads, such as printers, computers, radios, etc. was instead used to provide power to a high-powered load such as a mini fridge of unknown manufacture.   c)  East end of the office. Inside of an employee's cubicle: An ISOBAR Relocatable Power Tap designed and listed for a high concentration of low powered loads, such as printers, computers, radios, etc. was instead used to provide power to a high-powered load such as a Soleil ceramic space heater, model number PTC-915B.