BRADENTON, FL —
OSHA Inspection: PIERCE MANUFACTURING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PIERCE MANUFACTURING, INC. in 1512 38TH AVE E, BRADENTON, FL 34208 (NAICS 336120). OSHA activity number 347372625.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIERCE MANUFACTURING, INC.
- Site address
- 1512 38TH AVE E
- City
- BRADENTON
- State
- FL
- ZIP
- 34208
- Mailing
- 1512 38TH AVE E, BRADENTON, FL 34208
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336120
- Employees
- 400
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 C01
- Issued
- Sep 19, 2024
- Abate by
- Nov 6, 2024
- Penalty
- Initial $6,913 · Current $0 Reduced
9000
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At 1512 38th Ave E, Bradenton, Florida: On or about March 26, 2024, the employer did not develop and implement a written worksite specific respiratory protection program for employees provided and required to use tight-fitting facepiece respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $6913
1910.134 E01
- Issued
- Sep 19, 2024
- Abate by
- Nov 6, 2024
- Penalty
- Initial $0 · Current $2,765
9000
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At 1512 38th Ave E, Bradenton, Fl:: On or about March 26, 2024, the employer did not provide a medical evaluation to determine each employees' ability to use a respiratory protection before requiring use, in that, employees involved in polishing/grinding cement floors were provided and required to use tight-fitting facepiece respirators.
Recent events (2)
- — I (S) $2765.2
- — Z (S) $0
1910.134 F01
- Issued
- Sep 19, 2024
- Abate by
- Nov 6, 2024
- Penalty
- Initial $0 · Current $2,765
9000
General-duty citation text
29 CFR 1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a)At 1512 38th Ave E, Bradenton, Fl: On or about March 26, 2024, the employer did not develop and implement a written worksite specific respiratory protection program for employees provided and required to use tight-fitting facepiece respirators.
Recent events (2)
- — I (S) $2765.2
- — Z (S) $0
1910.134 K01
- Issued
- Sep 19, 2024
- Abate by
- Nov 6, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(k)(1):The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): a) At 1512 38th Ave E, Bradenton, Fl:: On or about March 26, 2024, the employer did not provide a medical evaluation to determine each employees' ability to use a respiratory protection before requiring use, in that, employees involved in polishing/grinding cement floors were provided and required to use tight-fitting facepiece respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Pierce Manufacturing, INC.
View Pierce Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336120)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347372625.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.