OSHA Inspection: EXEL INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EXEL INC. in 101 COMMERCE DRIVE, CARLISLE, PA 17015 (NAICS 493110). OSHA activity number 347380016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Exel INC. — free Get an email when a new federal OSHA severe-injury report for Exel INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EXEL INC.
Site address
101 COMMERCE DRIVE
City
CARLISLE
State
PA
ZIP
17015
Mailing
101 COMMERCE DRIVE ATTN: LINDSAY CZARNECKI, MECHANICSBURG, PA 17050
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.176 B

Other-than-serious Gravity 1 1 instance 35 exposed
Issued
Aug 22, 2024
Abate by
Oct 9, 2024
Penalty
Initial $5,876 · Current $3,750 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:  a.)  Warehouse - On or about March 28, 2024, employees are exposed to struck-by and crushing hazards where industrial storage racks were visibly damaged with bent and twisted beams and columns, missing beam clips, and damaged or missing anchor bolts in locations included, but are not limited to:  Aisles - C31, F3, F6, F25, F45, G1, G31, G34, J39, K1 of Racking System in center of warehouse by dock doors.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $3750
  • — Z (S) $5876

1910.304 G05

Other-than-serious Gravity 1 1 instance 35 exposed
Issued
Aug 22, 2024
Penalty
Initial $4,995 · Current $3,750 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) 101 Commerce Drive, Carlisle, PA - Dock Doors, - On or about March 28, 2024, the flexible cord for three  Prolight  Slim 30-Watt LED Work Light (Model 411030) were missing the grounding pin, exposing employees to an electrical hazard.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $3750
  • — Z (S) $4995