WELLSTON, OH —
OSHA Inspection: LEELLA OF WELLSTON
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LEELLA OF WELLSTON in 15 NORTH PARK AVENUE, WELLSTON, OH 45692 (NAICS 713950). OSHA activity number 347394306.
Where did this inspection happen?
- Establishment
- LEELLA OF WELLSTON
- Site address
- 15 NORTH PARK AVENUE
- City
- WELLSTON
- State
- OH
- ZIP
- 45692
- Mailing
- 1428 US HIGHWAY 22, WASHINGTON COURT HOUSE, OH 43160
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713950
- Employees
- 9
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not assess the workplace to include but not limited to various pin spotter machines, landscaping and processes that included the handling of chemicals to determine if hazards were present which would necessitate the use of personal protective equipment. Employees that perform work on mechanical equipment, perform facility landscaping and utilize various chemicals for cleaning of the equipment without the workplace conditions being assessed to determine the need for and type of PPE needed.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $5531.00 · Current $2766.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not establish a program for the control hazardous energy that included energy control procedures, employee training, or periodic inspections. Employees perform regular maintenance, cleaning and clearing of jams on pin spotter machines without a hazardous energy control program in place which exposes the employees to potential hazards associated with the unexpected equipment startup or release of stored energy.
Recent events (2)
- — I (S) $2765.5
- — Z (S) $5531
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, employees were exposed to machine hazards associated with moving parts, pinch points, and electrical shock hazards during servicing and maintenance tasks on the pin spotter machines. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect plug [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control element, involving verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Penalty
- Initial $3687.00 · Current $1844.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i):Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment. a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not ensure the unused knockouts of an electrical panel labeled BX3 located on the left wall as soon as you walk into the back room were effectively closed to protect the employees from electrical shock hazards.
Recent events (2)
- — I (S) $1843.5
- — Z (S) $3687
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not develop a written hazard communication program when employees were utilizing chemicals for periodic cleaning and maintenance of machinery, exposing employees to potential health hazards.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not provide information and training including but not limited to labeling requirements and the location of SDS's for employees that utilize chemicals for periodic cleaning and maintenance of machinery, exposing employees to potential health hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 A
- Issued
- Abate by
- Penalty
- Initial $922.00 · Current $461.00 Reduced
General-duty citation text
29 CFR 1904.32(a): The employer did not ensure that at the end of the year that entries were complete and accurate; and an annual summary of injuries and illnesses on the OSHA 300 Log was created, certified and posted. a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 18, 2024, the employer did not ensure that an OSHA 300A summary for the calendar year 2023 was created, certified and posted in a conspicuous place for the employees to view at the establishment.
Recent events (2)
- — I (O) $461
- — Z (O) $922
1904.39 A02
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $2305.00 Reduced
General-duty citation text
29 CFR 1904.39(a)(2):Basic Requirement. Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA. a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about December 16, 2023, the employer failed to report a in-patient hospitalization of one of their employees within 24 hours of the accident occurring.
Recent events (2)
- — I (O) $2305
- — Z (O) $4610
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.) a. Located at 15 North Park Avenue, Wellston, Ohio 45692: On or about April 5, 2024, the employer did not provide up to date safety data sheets (SDS) for each hazardous chemical used in the workplace to include but not limited to Klean Strip acetone and brake parts cleaner being used in the backroom of the establishment on a daily or weekly basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 713950)
CUPERTINO, CA—2026-06-16 00:00:00
LUCKY STRIKE ENTERTAINMENT CORPORATION
CROSSVILLE, TN—2026-06-02 00:00:00
PLATEAU BOWLING LANES, INC.
BELTON, MO—2026-05-05 00:00:00
AARON'S FAMILY FUN CENTER
TURLOCK, CA—2026-03-06 00:00:00
TEN PIN FUN CENTER
CLARKSTON, WA—2026-03-04 00:00:00
WA317990117 - BANANA BELT GAMING LLC
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347394306.