OSHA Inspection: AMERICOLD LOGISTICS PLOVER

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMERICOLD LOGISTICS PLOVER in 10953 STATE HIGHWAY 54, WISCONSIN RAPIDS, WI 54494 (NAICS 493120). OSHA activity number 347399461.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Americold Logistics Plover — free Get an email when a new federal OSHA severe-injury report for Americold Logistics Plover is published. One employer, no account, unsubscribe in one click.
Site address
10953 STATE HIGHWAY 54
City
WISCONSIN RAPIDS
State
WI
ZIP
54494
Mailing
10953 STATE HIGHWAY 54, WISCONSIN RAPIDS, WI 54494
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
72
Ownership type
A

3 citations on file for this inspection.

1910.119 L05

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Sep 4, 2024
Abate by
Oct 24, 2025
Penalty
Initial $10,775 · Current $2,000 Reduced
1910.119(l)(5)  If a change covered by this paragraph results in a change in the operating procedures or practices required by paragraph (f) of this section, such procedures or practices shall be updated accordingly.  On or about August 14, 2024; at a facility located at 10953 Wisconsin 54 in Plover, WI; the employer did not review operating procedures as often as necessary to assure that they reflected current operating practices including changes in process equipment. The operating procedure "Americold System Entire Operating Procedure", Sections "Engine Room Normal Shutdown" and "Engine Room Manual Shutdown" had not been reviewed to assure the steps, which included turning off V-3 (Vessel 3), reflected current operating practice. Vessel V-3 had been removed from service and employees were preforming normal shutdowns that were not reflected by the operating procedures.
Recent events (3)
  • — F (O) $2000
  • — C (S) $10775
  • — Z (S) $10775

1910.119 D03 II

Deleted Other-than-serious 2 instances 5 exposed
Issued
Sep 4, 2024
Abate by
Oct 2, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.119(d)(3)(ii):  The employer shall document that equipment complies with recognized and generally accepted good engineering practices:  On or about August 14, 2024, at a facility located at 10953 Wisconsin 54 in Plover, WI; the employer did not document that equipment complies with recognized and generally accepted good engineering practices (RAGAGEP):  a) Portions of pipping associated with the anhydrous ammonia refrigeration system:  The relief vent (RV) piping branch at Compressor 2 (CP-2); high stage discharge (HSD) piping branches and headers and high pressure liquid (HPL) piping branches at the Evaporative Condensers (EC-1 and EC-2). The employer failed to document compliance with employer's chosen RAGAGEP including IIAR 2 (2021) - Standard for design of Safe Close-Circuit Ammonia Refrigeration Systems, Section 5.14.3, 5.14.6 and Appendix Q when portions of the piping used in the anhydrous ammonia refrigeration system were not labeled or identified with the physical state (e.g. liquid or vapor), pressure level (e.g. high or low), or directional arrow indicating direction of flow.  b) A vessel associated with the anhydrous ammonia refrigeration system:  High Pressure Thermosyphon Receiver (V -5). The employer failed to document compliance with employer's chosen RAGAGEP including IIAR 2 (2021) - Standard for design of Safe Close-Circuit Ammonia Refrigeration Systems, Section 5.14.3 and Appendix Q when a vessel used in the anhydrous ammonia refrigeration system was not labeled or identified with the vessels name (e.g. Thermosyphon Receiver) and pressure level (e.g. high or low).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.119 J02

Deleted Other-than-serious 1 instance 5 exposed
Issued
Sep 4, 2024
Abate by
Oct 2, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.119(j)(2):  The employer shall establish and implement written procedures to maintain the on-going integrity of process equipment:  On or about August 14, 2024; at a facility located at 10953 Wisconsin 54 in Plover, WI; the employer did not establish written procedures for the inspection of insulated and non-insulated ammonia vessels and pipping. The employer relied upon third-party contractors to carry out nondestructive testing (NDT) and corrosion under insulation (CUI) inspections of ammonia refrigeration piping and vessels. The employer failed to establish written procedures for the NDT and CUI inspections as part of the employer's Mechanical Integrity Program.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Americold Logistics Plover's full OSHA safety record →