Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: KEYSTONE PLASTICS INC OF NEW YORK

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KEYSTONE PLASTICS INC OF NEW YORK in 3451 SOUTH CLINTON AVENUE, SOUTH PLAINFIELD, NJ 07080 (NAICS 339994). OSHA activity number 347409294.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keystone Plastics INC of NEW York for free Get an email when a new federal OSHA severe-injury report for Keystone Plastics INC of NEW York is published. One employer, no account, unsubscribe in one click.
Site address
3451 SOUTH CLINTON AVENUE
City
SOUTH PLAINFIELD
State
NJ
ZIP
07080
Mailing
3451 SOUTH CLINTON AVENUE, SOUTH PLAINFIELD, NJ 07080
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339994
Employees
148
Ownership type
Private (A)

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 27, 2024
Penalty
Initial $15,970 · Current $11,179 Reduced
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  A) 3451 S Clinton Ave South Plainfield, NJ 07080       All Pro 2 AAB (Picker) unit  The interlock on the D-2 Winder cabinet door was not in proper working order. When the cabinet door was open the unit didn't stop as the interlock was physically overridden. This condition exposed employees to amputation hazards.   Hazard noted on or about 04/12/24
Recent events (2)
  • · I (S) $11179
  • · Z (S) $15970

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347409294.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.