CONWAY, AR —
OSHA Inspection: TOKUSEN USA, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TOKUSEN USA, INC in 1500 SOUTH AMITY ROAD, CONWAY, AR 72032 (NAICS 331222). OSHA activity number 347429417.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOKUSEN USA, INC
- Site address
- 1500 SOUTH AMITY ROAD
- City
- CONWAY
- State
- AR
- ZIP
- 72032
- Mailing
- 1500 SOUTH AMITY ROAD, CONWAY, AR 72032
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331222
- Employees
- 265
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $16,131 · Current $12,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about April 10, 2024, on the production floor, employees performed servicing and maintenance on the Fine Wire machine #FD-38 using deficient hazardous energy control procedures in that: (a) The procedures did not include a statement of intended use. (b) The procedures did not include specific steps for control all hazardous energy. (c) The procedures did not include steps for restoring energy to the machine or equipment.
Recent events (2)
- — I (S) $12000
- — Z (S) $16131
More inspections at Tokusen USA, INC