OSHA Inspection: PORCELEN LIMITED CONNECTICUT, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PORCELEN LIMITED CONNECTICUT, LLC in 129 LEEDER HILL DRIVE, HAMDEN, CT 06517 (NAICS 325510). OSHA activity number 347447187.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Porcelen Limited Connecticut, LLC — free Get an email when a new federal OSHA severe-injury report for Porcelen Limited Connecticut, LLC is published. One employer, no account, unsubscribe in one click.
Site address
129 LEEDER HILL DRIVE
City
HAMDEN
State
CT
ZIP
06517
Mailing
333 WELTON STREET, HAMDEN, CT 06517
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
325510
Employees
26
Ownership type
A

7 citations on file for this inspection.

1910.106 E09 III

Serious Gravity 1 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $5,323 · Current $2,662 Reduced
29 CFR 1910.106(e)(9)(iii):  Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  Primer Room:  On or about April 30, 2024, employees were exposed to fire and smoke hazards from discarded rags soiled with MEK (methyl ethyl ketone) and combustible materials placed in uncovered waste pails.
Recent events (2)
  • — I (S) $2661.5
  • — Z (S) $5323

1910.147 C06 I

Deleted Serious Gravity 1 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $5,323 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:  Facility: On or about April 30, 2024, the employer had not conducted a periodic inspection of the energy control procedures for the coil line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5323

1910.212 A01

Serious Gravity 10 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $12,421 · Current $6,211 Reduced
29 CFR1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  Primer Room:  On or about April 17, 2024, an employee was exposed to an unguarded ingoing nip point on the GFG coil roller machine while performing maintenance and suffered a severe hand injury.
Recent events (2)
  • — I (S) $6210.5
  • — Z (S) $12421

1910.219 C02 I

Serious Gravity 5 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $8,873 · Current $4,437 Reduced
29 CFR 1910.219(c)(2)(i):  All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.  Primer Room:  On or about April 30, 2024, employees were exposed to direct-drive horizontal shafts on the GFG coil roller machine with inadequate safeguarding.
Recent events (2)
  • — I (S) $4436.5
  • — Z (S) $8873

1910.303 G02 I

Serious Gravity 1 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $5,323 · Current $2,662 Reduced
29 CFR 1910.303(g)(2)(i):  Live�parts of�electric equipment�operating at�50-volts,�or more�were not guarded against�accidental contact by�approved cabinets�or other�forms of�approved enclosures,�or other means listed under this provision:  Outside Primer Room:  On or about April 30, 2024, employees were exposed to 230/460-volt electrical hazards walking and working around a Baldor Reliance inverter motor unit with an electrical cover not properly secured.
Recent events (2)
  • — I (S) $2661.5
  • — Z (S) $5323

1910.147 C04 I

Serious Gravity 10 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $24,842 · Current $12,421 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of hazardous energy when employees were engaged in activities such as servicing and/ or maintenance of equipment:  Primer Room:  On or about April 30, 2024, the employer exposed an employee to amputation hazards in that the employer failed to ensure specific lockout tagout procedures were utilized while cleaning the GFG coil rollers resulting in severe hand injuries.  Specrail was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 1477516, citation number 1, item number 1 and was affirmed as a final order on December 30, 2020, with respect to a workplace located at 129 Leeder Hill Road Hamden, CT 06517.
Recent events (2)
  • — I (S) $12421
  • — Z (R) $24842

1904.39 A02

Deleted Other-than-serious 1 instance 26 exposed
Issued
Aug 20, 2024
Abate by
Sep 16, 2024
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR1904.39(a)(2):  The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.    Facility:  On or about April 30, 2024, the employer did not notify Federal OSHA within 24 hours of an employee in-patient hospitalization due to a workplace incident.
Recent events (2)
  • — I (O) $0
  • — Z (O) $8873

View Porcelen Limited Connecticut, LLC's full OSHA safety record →