SURING, WI —
OSHA Inspection: DIMENSION LUMBER COMPANY, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DIMENSION LUMBER COMPANY, LLC in 11852 STATE HIGHWAY 32 EAST, SURING, WI 54174 (NAICS 321113). OSHA activity number 347457012.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIMENSION LUMBER COMPANY, LLC
- Site address
- 11852 STATE HIGHWAY 32 EAST
- City
- SURING
- State
- WI
- ZIP
- 54174
- Mailing
- 11852 STATE HIGHWAY 32E, SURING, WI 54174
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 30
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.265 C04 V
- Issued
- Sep 20, 2024
- Penalty
- Initial $4,839 · Current $2,902 Reduced
General-duty citation text
29 CFR 1910.265(c)(4)(v): Where elevated platforms are used routinely on a daily basis, they shall be equipped with stairways or fixed ladders that comply with 29 CFR part 1910, subpart D. See 29 CFR 1910.23(b)(1): The employer must ensure that ladder rungs, steps, and cleats are parallel, level, and uniformly spaced when the ladder is in position for use. a) On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; near the Gang Saw, the employer did not ensure that the ladder rungs on the fixed ladder used to access the Gang Saw were uniformly spaced, exposing employees to fall hazards.
Recent events (2)
- — I (S) $2902
- — Z (S) $4839
1910.265 C05
- Issued
- Sep 20, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(c)(5)(i): Stairways shall be constructed in accordance with 29 CFR part 1910, Subpart D. In accordance with 29 CFR 1910.25(b)(1) Handrails, stair rail systems, and guardrail systems are provided in accordance with 29 CFR 1910.28, 29 CFR 1910.25(b)(3) Stairs have uniform riser heights and tread depths between landings, and 29 CFR 1910.28(b)(11)(iii): Each ship stairs and alternating tread type stairs is equipped with handrails on both sides. On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that stairways were constructed in accordance with 29 CFR 1910, Subpart D, exposing employees to fall hazards in the following instances: a) The stairway providing access to the Big Trimmer and Small Trimsaw was not equipment with handrails on both sides, exposing employees to fall hazards. b) The stairway providing access to the Edger did not have uniform riser heights between landings, exposing employees to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II
- Issued
- Sep 20, 2024
- Abate by
- Oct 21, 2024
- Penalty
- Initial $8,067 · Current $4,840 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to (c)(4)(ii)(A) through (c)(4)(ii)(D) of this section. On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that the equipment specific energy control procedures clearly and specifically outlined the rules and techniques necessary to control hazardous energy for employees who perform servicing and/or maintenance operations, such as but not limited to changing blades, exposing employees to contact with hazardous energies in the following instances: a) The energy control procedure for the 5-Head Brewer Bandsaw (Manufacturer: Brewer, Inc., Model: 5HD Bandsaw, SN: 071806) did not clearly and specifically outline the rules and techniques necessary to control hazardous energy for employees who perform servicing and/or maintenance operations and the magnitude of hazardous energies. b) The energy control procedure for the Splitter Saw (Manufacturer: In-House Fabrication) did not clearly and specifically outline the rules and techniques necessary to control hazardous energy for employees who perform servicing and/or maintenance operations and the magnitude of hazardous energies.
Recent events (2)
- — I (S) $4840
- — Z (S) $8067
1910.147 D
- Issued
- Sep 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). a) On or about May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; an employee was exposed to machine hazards associated with moving parts when they engaged in blade changing on the 5-Head Brewer Bandsaw (Manufacturer: Brewer, Inc., Model: 5HD Bandsaw, SN: 071806). The employer did not ensure that an employee had implemented energy control application steps or equivalent protective measures prior to allowing them to perform blade changing. The machine was not isolated, such as but not limited to electrical, prior to the employee engaging in the servicing / maintenance activity. b) On or about May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; an employee was exposed to machine hazards associated with moving parts when they engaged in blade changing on the Splitter Saw (Manufacturer: In-House Fabrication). The employer did not ensure that an employee had implemented energy control application steps or equivalent protective measures prior to allowing them to perform blade changing. The machine was not isolated, such as but not limited to electrical, prior to the employee engaging in the servicing / maintenance activity. c) On or about May 1, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; an employee was exposed to machine hazards associated with moving parts when they engaged in blade changing on the Splitter Saw (Manufacturer: In-House Fabrication). The employer did not ensure that an employee had implemented energy control application steps or equivalent protective measures prior to allowing them to perform blade changing. The machine was not isolated, such as but not limited to electrical, prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 I03
- Issued
- Sep 20, 2024
- Abate by
- Oct 28, 2024
- Penalty
- Initial $8,067 · Current $4,840 Reduced
General-duty citation text
29 CFR 1910.213(i)(3): Feed rolls of band resaws shall be protected with a suitable guard to prevent the hands of the operator from coming in contact with the in-running rolls at any point. The guard shall be constructed of heavy material, preferably metal, and the edge of the guard shall come to within three-eighths inch of the plane formed by the inside face of the feed roll in contact with the stock being cut. a) On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that the hold downs on the 5-Head Brewer Bandsaw (Manufacturer: Brewer, Inc., Model: 5HD Bandsaw, SN: 071806) and the 4-Head Brewer Bandsaw (Manufacturer: Brewer, Inc., Model: BR 4B8X12R, SN: 081695) were adequately guarded, exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $4840
- — Z (S) $8067
1910.265 E04 II A
- Issued
- Sep 20, 2024
- Abate by
- Oct 21, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(e)(4)(ii)(a): Trimmer saws shall be guarded in front by adequate baffles to protect against flying debris and they shall be securely bolted to a substantial frame. These guards for a series of saws shall be set as close to the top of the trimmer table as is practical. a) On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that the Little Trimsaw (Manufacturer: Cornell, Model: Trimsaw 2 Head, SER: #STOB-364-3-05) was guarded in the front by adequate baffles to protect against flying debris, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 E04 II B
- Issued
- Sep 20, 2024
- Abate by
- Oct 21, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(e)(4)(ii)(b): The end saws on trimmer shall be guarded. a) On or about and at times prior to May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that the end saw on the Little Trimsaw (Manufacturer: Cornell, Model: Trimsaw 2 Head, SER: #STOB-364-3-05) was adequately guarded, exposing employees to contact with point of operation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 E04 II C
- Issued
- Sep 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(e)(4)(ii)(c): The rear of trimmer saws shall have a guard the full width of the saws and as much wider as practical. a) On or about May 2, 2024, at the establishment located at 11852 State Highway 32 East, Suring, Wisconsin; the employer did not ensure that the rear of the Big Trimmer (Manufacturer: Cornell, Model: Trimsaw 4 Head Trimmer, SER: #MSTB-316-11-98) and the Little Trimsaw (Manufacturer: Cornell, Model: Trimsaw 2 Head, SER: #STOB-364-3-05) were adequately guarded, exposing employees to contact with point of operation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Dimension Lumber Company, LLC
View Dimension Lumber Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347457012.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.