Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDSTATE MANUFACTURING COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MIDSTATE MANUFACTURING COMPANY in 750 W 3RD ST., GALESBURG, IL 61401 (NAICS 332710). OSHA activity number 347457483.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midstate Manufacturing Company — free Get an email when a new federal OSHA severe-injury report for Midstate Manufacturing Company is published. One employer, no account, unsubscribe in one click.
Site address
750 W 3RD ST.
City
GALESBURG
State
IL
ZIP
61401
Mailing
750 W 3RD ST., GALESBURG, IL 61401
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
248
Ownership type
A

10 citations on file for this inspection.

1910.23 E01 VII

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $6,222 · Current $4,355 Reduced
29 CFR 1910.23(e)(1)(vii): The employer did not ensure that mobile ladder stands and platforms that have wheels or casters are equipped with a system to impede horizontal movement when an employee is on the stand or platform:  On or about May 3, 2024, employees using mobile ladder to access the wash bay are exposed to slip, trip, and fall hazards because the employer does not ensure the mobile ladder has wheels or casters equipped with a working system to impede horizontal movement when an employee is on the stand or plat form.
Recent events (2)
  • — I (S) $4355.4
  • — Z (S) $6222

1910.146 C04

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $10,372 · Current $0 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146.  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10372

1910.146 C05 II C

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(5)(ii)(C): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument:   a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not perform air monitoring prior to entry.  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not perform air monitoring prior to entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 E01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:   a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:  a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146.  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $10,372 · Current $7,260 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not ensure procedures were utilized for the control of potentially hazardous energy.  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not ensure procedures were utilized for the control of potentially hazardous energy.
Recent events (2)
  • — I (S) $7260.4
  • — Z (S) $10372

1910.147 C07 I A

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $10,372 · Current $0 Reduced
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate.  a) On or about May 3, 2024, employees performed cleaning activities in the oven and the employer did not provide training to ensure authorized employees in the  recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate.  b) On or about May 3, 2024, employees performed cleaning and maintenance activities in the wash bay and the employer did not provide training to ensure authorized employees in the  recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10372

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $6,222 · Current $4,355 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about May 3, 2024, employees were exposed to embolism hazards because the compressed air used for cleaning purposes exceeded 30 p.s.i.
Recent events (2)
  • — I (S) $4355.1
  • — Z (S) $6222

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $6,222 · Current $4,355 Reduced
29 CFR 1910.305(g)(1)(iv)(A) :Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about May 3, 2024, employees working with the sandblaster in Building 4 were exposed to electrical hazards because the employer allowed flexible cords to be used as a substitute for the fixed wiring of the sandblaster.
Recent events (2)
  • — I (S) $4355.1
  • — Z (S) $6222

1910.305 G01 IV D

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 21, 2024
Abate by
Dec 12, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:  On or about May 3, 2024, employees working with the sandblaster in Building 4 were exposed to electrical hazards because the employer allowed flexible cords to be attached to building surfaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Midstate Manufacturing Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347457483.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.