Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES POSTAL SERVICE, WEST SACRAMENTO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED STATES POSTAL SERVICE, WEST SACRAMENTO in 3775 INDUSTRIAL BLVD, WEST SACRAMENTO, CA 95799 (NAICS 491110). OSHA activity number 347462707.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Postal Service, West Sacramento — free Get an email when a new federal OSHA severe-injury report for United States Postal Service, West Sacramento is published. One employer, no account, unsubscribe in one click.
Site address
3775 INDUSTRIAL BLVD
City
WEST SACRAMENTO
State
CA
ZIP
95799
Mailing
3775 INDUSTRIAL BLVD, WEST SACRAMENTO, CA 95799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
1200
Ownership type
A

6 citations on file for this inspection.

1910.147 C08

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
May 29, 2024
Abate by
Jun 17, 2024
Penalty
Initial $15,211 · Current $0 Reduced
29 CFR 1910.147(c)(8): Lockout or tagout was not performed by the authorized employee who was performing servicing or maintenance.  Low-Cost Encoder Machine: On or about May 6. 2024, an employee was observed servicing LCREM 1(serial no. LR107) without performing a Lockout Tagout (LOTO) procedure. This condition potentially exposed employee(s) to crushing, laceration and or amputation hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $15211

1910.184 C14

Other-than-serious Gravity 5 1 instance 10 exposed
Issued
May 29, 2024
Abate by
Jun 10, 2024
Penalty
Initial $10,140 · Current $7,098 Reduced
29 CFR 1910.184(c)(14): The employer was using a sling without affixed and legible identification markings.  Battery Servicing/Changing Room:  On and/or before May 6th, 2024, employee(s) used wire rope slings to change out forklift batteries.  In the battery servicing room, a sling with no identification markings was being used to change out batteries.  This condition potentially exposed employee(s) to crushing hazards.
Recent events (2)
  • — I (O) $7098
  • — Z (S) $10140

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
May 29, 2024
Penalty
Initial $7,604 · Current $5,323 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Employee Break Room: On and/or before May 6th, 2024, Employee(s) store consumable items in the Hotpoint Refrigerator.  An orange extension cord was being used to power a refrigerator and not per its manufactures requirements to be plugged into an approved wall outlet. Employees were potentially exposed to electrical and/or fire hazard(s).
Recent events (2)
  • — I (S) $5323
  • — Z (S) $7604

1910.303 G01

Serious Gravity 1 2 instances 25 exposed
Issued
May 29, 2024
Abate by
Jun 10, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  On or about May 6, 2024, electrical panels were blocked, this condition interferes with access and immediate shutdown of a circuit in the panel, particularly in the event of an emergency.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).    In the following locations: 1. In the "ET aisle" of the main processing floor. A maintenance toolbox was blocking electrical panel 2L0CR2 2. In the induction room, 2 guards bolted to the floor were blocking electrical panel 2L1H
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 B

Deleted Other-than-serious 3 instances 50 exposed
Issued
May 29, 2024
Abate by
Jun 10, 2024
Penalty
Initial $1,423 · Current $0 Reduced
29 CFR 1910.151(b): The employer did not ensure that adequate first aid supplies were readily available.  On and/or before May 6, 2024, employee(s) did not have immediate access to first aid supplies on the work floor without a manager's key to the locked first aid kit(s) to treat injuries occurred during work operations. This condition potentially exposed employee(s) to the inability of timely access to first aid supplies which in turn could exacerbate injuries.  In the following locations: (a) On the main entrance wall/Green wall.  (b) On a work bench near OPN 918. (c) In the battery storage/servicing room.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1423

1910.1200 E01 I

Other-than-serious 1 instance 10 exposed
Issued
May 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1)(i): A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet was not provided.   On or about May 6. 2024, in the CTC room, the employer did not ensure that the chemicals contained in the SDS binder were listed. Employees were potentially exposed to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View United States Postal Service, West Sacramento's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347462707.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.