CAPE GIRARDEAU, MO —
OSHA Inspection: SPARTECH LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SPARTECH LLC in 2500 SPARTECH DR., CAPE GIRARDEAU, MO 63701 (NAICS 326130). OSHA activity number 347463549.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPARTECH LLC
- Site address
- 2500 SPARTECH DR.
- City
- CAPE GIRARDEAU
- State
- MO
- ZIP
- 63701
- Mailing
- 2500 SPARTECH DR., CAPE GIRARDEAU, MO 63701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326130
- Employees
- 55
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about 5/1/2024, an employee was exposed to hazardous energy while conducting service work on a Knife Gate (SN: 11-OG4087/ MN: OG400) due to moving parts of the machine. The employer did not ensure the the energy control procedures clearly and specifically outlined steps for shutting down, Isolating, blocking and securing machines or equipment to control hazardous energy for the Knife Gate (SN: 11-OG4087/ MN: OG400) that is part of Line 1 in the hopper area on the mezzanine. Specific energy control procedures did not exist for the following items in the: - Specific steps for shutting down the machines under normal conditions - Specific locations and steps on the machine to isolate energy sources - Specific steps for releasing the stored energy for the machines - Specific steps to verify machine has hazardous energy controlled
Recent events (3)
- — R (S) $0
- — C (S) $16131
- — Z (S) $16131
1910.147 D03
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $16,131
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about 5/1/2024, an employee was exposed to hazardous energy while conducting service work on a Knife Gate (SN: 11-OG4087/ MN: OG400) due to moving parts of the machine. The employees did not take the steps necessary to control the hazardous energy and isolate the machine prior to removing a guard and preforming maintenance on the Knife Gate Machine. Amended to: The classification of Citation 1, Item 1b shall remain serious as issued. The ADV is amended to ?On or about 5/1/2024, a maintenance employee was troubleshooting a Knife/Slide Gate and did not ensure the surrounding mezzanine area was clear of affected employees pursuant to internal company procedures.? Citation 1, Item 1(b) shall be amended to a section 5(a)(1) violation of the OSH Act.
Recent events (3)
- — R (S) $16131
- — C (S) $0
- — Z (S) $0
1910.147 D06
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: On or about 5/1/2024, an employee was exposed to hazardous energy while conducting service work on a Knife Gate (SN: 11-OG4087/ MN: OG400) due to moving parts of the machine. The employees did not take the steps necessary to verify the hazardous energy was controlled on the machine prior to removing a guard and preforming maintenance on the Knife Gate Machine.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I A
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $11,524 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: On or about 5/8/2024, the employer did not ensure that the periodic inspections of the energy control procedure were performed by an authorized employee other other than the one utilizing the energy control procedure being inspected. The periodic inspections from 1/1/2023 through 5/14/2024 were preformed by authorized employee that utilizes the same energy control procedures being inspected.
Recent events (3)
- — R (S) $0
- — C (S) $11524
- — Z (S) $11524
1910.147 C06 I C
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. On or about 5/8/2024, the employer did not ensure that where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. The periodic inspections from 1/1/2023 through 5/14/2024 were preformed by authorized employee that utilizes the same energy control procedures being inspected and did not involve any other authorized employees.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I D
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(D): Where tagout was used for energy control, the periodic inspection did not include a review between the inspector and each authorized and affected employee of the employee's responsibilities under the energy control procedure. On or about 5/8/2024, the employer did not ensure that where tagout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. The periodic inspections from 1/1/2023 through 5/14/2024 did not involve other authorized or affected employees.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $11,524 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: On or about 5/1/2024, an employee was exposed to hazardous energy while conducting service work on a Knife Gate (SN: 11-OG4087/ MN: OG400) due to moving parts of the machine. The employer did not provide adequate training to ensure that employees had the knowledge and skills required for the safe application, usage and removal of energy control devices for the Knife Gate Machine.
Recent events (3)
- — R (S) $0
- — C (S) $11524
- — Z (S) $11524
1910.132 D02
- Issued
- Jun 17, 2024
- Abate by
- Jul 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and which identifies the document as a certification of hazard assessment: On or about 5/8/2024, the employer did not verify that the required workplace hazard assessment had been performed through a written certification and contained the required information. The PPE Plant Hazard Assessment Matrix did not contain the person preforming the evaluation and the dates the assessment was completed.
Recent events (3)
- — R (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Spartech LLC
View Spartech LLC's full OSHA safety record →
More inspections in this industry (NAICS 326130)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347463549.