Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VOESTALPINE PRECISION STRIP WI., INC

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of VOESTALPINE PRECISION STRIP WI., INC in 7888 102ND STREET, PLEASANT PRAIRIE, WI 53158 (NAICS 332811). OSHA activity number 347473621.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Voestalpine Precision Strip WI., INC — free Get an email when a new federal OSHA severe-injury report for Voestalpine Precision Strip WI., INC is published. One employer, no account, unsubscribe in one click.
Site address
7888 102ND STREET
City
PLEASANT PRAIRIE
State
WI
ZIP
53158
Mailing
7888 102ND STREET, PLEASANT PRAIRIE, WI 53158
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
55
Ownership type
A

4 citations on file for this inspection.

1910.1025 C01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Oct 11, 2024
Abate by
Feb 28, 2025
Penalty
Initial $9,697 · Current $0 Reduced

Hazardous substances 1591

29 CFR  1910.1025(c)(1): Employee(s) were exposed to lead at concentrations greater than fifty micrograms per cubic meter of air averaged over an eight-hour period:  (a) On August 19, 2024, an employee engaged in furnace maintenance operations was exposed to an 8-hour time weighted average (TWA) of 73.4 ug/m3 for lead, approximately 1.5 times the Permissible Exposure Limit (PEL) of 50 ug/m3. The exposure level was derived from a sample collected over a 461 minute sampling period, with zero exposure assumed for the unsampled period of 19 minutes.  (b) On August 19, 2024, an employee engaged in furnace maintenance operations was exposed to an 8-hour time weighted average (TWA) of 52.1 ug/m3 for lead, approximately 1.04 times the Permissible Exposure Limit (PEL) of 50 ug/m3. The exposure level was derived from a sample collected over a 462 minute sampling period, with zero exposure assumed for the unsampled period of 18 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9697

1910.1025 D06 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 11, 2024
Abate by
Feb 28, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR  1910.1025(d)(6)(iii): Where the initial monitoring revealed that employee exposure to lead was above the permissible exposure limit, monitoring was not repeated at least quarterly and continued at the required frequency until at least two consecutive measurements taken at least 7 days apart were below the PEL and at or above the action level:  (a) On or about May 10, 2024, the employer did not perform air sampling quarterly (every 3 months) when employee exposure to airborne concentrations of lead was above the PEL during scheduled furnace maintenance operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 11, 2024
Abate by
Feb 28, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR  1910.1025(e)(1):The employer did not implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead:  (a) On August 19, 2024, the engineering controls (including administrative controls) were not effective to keep employee exposures under the PEL for lead during scheduled furnace maintenance operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 I03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 11, 2024
Abate by
Nov 7, 2024
Penalty
Initial $9,697 · Current $5,818 Reduced

Hazardous substances 1591

29 CFR  1910.1025(i)(3)(i): The employer shall assure that employees who work in areas where their airborne exposure to lead is above the PEL, without regard to the use of respirators, shower at the end of the work shift.  (a) On or about May 16th, 2024, the employer did not ensure that the furnace maintenance employees that are exposed to levels of lead above the PEL took showers at the end of their work shift.
Recent events (2)
  • — I (S) $5818
  • — Z (S) $9697

View Voestalpine Precision Strip WI., INC's full OSHA safety record →