Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APPLE ROOFING SOLUTIONS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of APPLE ROOFING SOLUTIONS LLC in 2408 CANTER LANE, GREEN BAY, WI 54304 (NAICS 238160). OSHA activity number 347508442.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apple Roofing Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Apple Roofing Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
2408 CANTER LANE
City
GREEN BAY
State
WI
ZIP
54304
Mailing
3305 SOUTH ASHBROOK STREET, APPLETON, WI 54915
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

12 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 8 exposed
Issued
Dec 31, 2024
Abate by
Feb 21, 2025
Penalty
Initial $427 · Current $427
29 CFR  1903.19(c)(1):Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.  On or about December 18, 2024, with respect to a worksite located at 2408/2410 & 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not certify to OSHA that the hazardous conditions related to head protection, eye protection, ladder usage and ladder training had been corrected to ensure employee safety.
Recent events (1)
  • — Z (O) $427

1903.19 D01

Other-than-serious 1 instance 8 exposed
Issued
Dec 31, 2024
Abate by
Feb 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1903.19(d)(1):The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  On or about December 18, 2024, with respect to a worksite located at 2408/2410 & 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not certify, and provide documentation demonstrating, to OSHA that the hazardous conditions related to fall protection systems, use of fall protection, fall protection training and access/egress from ladders had been corrected to ensure employee safety.
Recent events (1)
  • — Z (O) $0

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $4,563 · Current $4,563
29 CFR  1926.100(a):Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, the employer did not ensure that an employee exposed to struck-by hazards from falling tools and material of the roofing work being conducted above was protected by a helmet.
Recent events (1)
  • — Z (S) $4563

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, employees were exposed to eye hazards from flying particles while using pneumatic nail guns to install asphalt shingles on a residential roof without any form of eye protection.
Recent events (1)
  • — Z (S) $0

1926.502 D15

Serious Gravity 5 3 instances 6 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $3,803 · Current $3,803
29 CFR  1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as identified in standards 1926.502(d)(15)(i)-1926.502(d)(15)(ii).  a) On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, the employer did not ensure that roof anchor being used as part of fall protection system above the unit labeled 2408 had been installed correctly and would support at least 5,000 pounds per attached employee. There was not a sufficient amount of fasteners installed in the anchor point, as prescribed in the manufacturer's instructions.   b) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not ensure that roof anchor being used as part of fall protection system above the unit labeled 2412 had been installed correctly and would support at least 5,000 pounds per attached employee. Two employees had lifelines attached to anchor point which would have increased the chance of an anchor failure during a fall emergency.   c) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not ensure that roof anchor being used as part of fall protection system above the unit labeled 2414 had been installed correctly and would support at least 5,000 pounds per attached employee. There was not a sufficient amount of fasteners installed in the anchor point, as prescribed in the manufacturer's instructions. Two employees had lifelines attached to anchor point which would have increased the chance of an anchor failure during a fall emergency.
Recent events (1)
  • — Z (S) $3803

1926.502 D16 III

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, shall be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level.  a) On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, the employer did not ensure the personal fall arrest systems were rigged so that the employees would not free fall more than 6 feet or contact the ground in the event of an unexpected fall. The rope grab portion of the fall protection system was connected at the end of the rope which would not have prevented the employee from contacting the ground during a fall.   b) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not ensure the personal fall arrest systems were rigged so that the employees would not free fall more than 6 feet or contact the ground in the event of an unexpected fall. The rope grab portion of the fall protection system was connected at the end of the rope which would not have prevented the employee from contacting the ground during a fall.
Recent events (1)
  • — Z (S) $0

1926.502 D21

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(21): Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.  a) On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, the employer did not ensure that components of personal fall arrest systems were inspected prior to use and that defective components were removed from service.  b) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not ensure that components of personal fall arrest systems were inspected prior to use and that defective components were removed from service.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $4,563 · Current $4,563
29 CFR  1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.   On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, an employee using a Gorilla Model GLMPXA-14 Multi-Position Ladder was exposed to fall hazards when the employer did not ensure that the employee used the ladder as designed. The employee was using the ladder in the step-ladder configuration and was observed standing on the top rung of each side of the ladder, increasing the chances of tipping the ladder during use.
Recent events (1)
  • — Z (S) $4563

1926.1060 A

Serious Gravity 5 2 instances 8 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.  a) On or about May 28, 2024, with respect to a worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, the employer did not ensure that employees exposed to potential fall hazards while using ladders had received training on ladder hazards and methods to mitigate those hazards prior to conducting hazardous operations.   b) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, the employer did not ensure that employees exposed to potential fall hazards while using ladders had received training on ladder hazards and methods to mitigate those hazards prior to conducting hazardous operations.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Willful Gravity 10 2 instances 7 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $35,491 · Current $35,491
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a) Apple Roofing Solutions, LLC does not require the use of fall protection during roofing operations. This violation was most recently observed on May 28, 2024, at a residential re-roofing project located at 2408/2410 Canter Lane, Green Bay, WI 54304. Employees were exposed to falls hazards of 9 feet 4 inches and greater while tearing off old roofing materials and installing new asphalt shingles without their harnesses being connected to lifelines.  b) Apple Roofing Solutions, LLC does not require the use of fall protection during roofing operations. This violation was most recently observed on May 28, 2024, at a residential re-roofing project located at 2412/2414 Canter Lane, Green Bay, WI 54304. Employees were exposed to falls hazards of 9 feet 4 inches and greater while tearing off old roofing materials and installing new asphalt shingles without their harnesses being connected to lifelines.  Apple Roofing Solutions LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 1623689, citation number 1, item number 1 and was affirmed as a final order on November 29, 2022, with respect to a workplace located at 4720 N Hastings Court, Appleton, Wisconsin.  Apple Roofing Solutions LLC was previously cited for a Willful violation of this occupational safety and health standard, which was contained in OSHA inspection number 1561429, citation number 2, item number 1 and was affirmed as a final order on March 11, 2022, with respect to a workplace located at 904/908 Jefferson Street in Algoma, Wisconsin.  Apple Roofing Solutions LLC was previously cited for a Repeat violation of this occupational safety and health standard, which was contained in OSHA inspection number 1531887, citation number 1, item number 1 and was affirmed as a final order on March 11, 2022, with respect to a workplace located at 218 Crestview Avenue, Neenah, WI 54956.
Recent events (1)
  • — Z (W) $35491

1926.503 A01

Willful Gravity 10 2 instances 7 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $35,491 · Current $35,491
29 CFR  1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a) Apple Roofing Solutions, LLC does not provide fall protection training to employees who are exposed to fall hazards greater than six feet while conducting roofing activities. This was most recently observed on May 28, 2024, at a residential worksite located at 2408/2410 Canter Lane, Green Bay, WI 54304, when three employees, who were not provided fall protection training by the employer, were exposed to a fall hazards of nine feet and greater while removing old shingles and installing new shingles on a residential building having a steep pitch roof without fall protection.  b) Apple Roofing Solutions, LLC does not provide fall protection training to employees who are exposed to fall hazards greater than six feet while conducting roofing activities. This was most recently observed on May 28, 2024, at a residential worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, when four employees, who were not provided fall protection training by the employer, were exposed to a fall hazards of nine feet and greater while removing old shingles and installing new shingles on a residential building having a steep pitch roof without fall protection.  Apple Roofing Solutions LLC was previously cited for a Repeat violation of this occupational safety and health standard or its equivalent standard (1926.503(b)(1)), which was contained in OSHA inspection number 1561429, citation number 3, item number 1 and was affirmed as a final order on March 11, 2022, with respect to a workplace located at 904/908 Jefferson Street in Algoma, Wisconsin.  Apple Roofing Solutions LLC was previously cited for a Repeat violation of this occupational safety and health standard or its equivalent standard (1926.503(b)(1)), which was contained in OSHA inspection number 1531887, citation number 1, item number 2 and was affirmed as a final order on March 11, 2022, with respect to a workplace located at 218 Crestview Avenue, Neenah, WI 54956.
Recent events (1)
  • — Z (W) $35491

1926.1053 B01

Repeat Gravity 5 1 instance 4 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $19,015 · Current $19,015
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a) On or about May 28, 2024, with respect to a worksite located at 2412/2414 Canter Lane, Green Bay, WI 54304, employees were exposed to falls of 9 feet, 4 inches while accessing the roof of a residential building using a Franklin Model 63418 Multi-Position Ladder that was not extended three feet above the landing surface nor was it secured to the roof with a grasping device provided.   Apple Roofing Solutions LLC was previously cited for a Serious violation of this occupational safety and health standard, which was contained in OSHA inspection number 1623689, citation number 1, item number 2 and was affirmed as a final order on November 29, 2022, with respect to a workplace located at 4720 N Hastings Court, Appleton, Wisconsin.  Apple Roofing Solutions LLC was previously cited for a Serious violation of this occupational safety and health standard, which was contained in OSHA inspection number 1561429, citation number 1, item number 1 and was affirmed as a final order on March 11, 2022, with respect to a workplace located at 904/908 Jefferson Street in Algoma, Wisconsin.
Recent events (1)
  • — Z (R) $19015

View Apple Roofing Solutions LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347508442.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.