Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HONEYWELL INTERNATIONAL INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of HONEYWELL INTERNATIONAL INC. in 5525 HWY 3115, GEISMAR, LA 70734 (NAICS 325180). OSHA activity number 347544702.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Honeywell International INC. — free Get an email when a new federal OSHA severe-injury report for Honeywell International INC. is published. One employer, no account, unsubscribe in one click.
Site address
5525 HWY 3115
City
GEISMAR
State
LA
ZIP
70734
Mailing
P.O. BOX 226, GEISMAR, LA 70734
Inspection type
Programmed Related (J)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.119 F04

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 26, 2024
Abate by
Dec 12, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1910.119(f)(4): The employer did not develop and implement safe work practices to control hazards during operations such as lockout/tagout, confined space entry, opening process equipment or piping, and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel.   On or about June 7, 2024, in the HFC-245fa Process Unit, the employer did not effectively implement procedures for properly implementing safe and effective lock-out/ tag-out and line opening, specifically block-bleed blind flange side of a closed bleed valve on the D reactor fresh feed system (Valve F105).
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

1910.147 D05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 26, 2024
Abate by
Dec 12, 2024
Penalty
Initial $23,048 · Current $23,048
29 CFR  1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained, or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices.  On or around June 7, 2024, on the fifth floor of Hydrofluoric Acid Unit 245 at Honeywell Geismar, the employer did not ensure that all potentially hazardous stored or residual energy was properly bled, disconnected, blocked, or otherwise made safe, specifically the block-bleed blind flange side of a closed bleed valve on the D reactor fresh feed system (Valve F105).
Recent events (3)
  • — F (S) $23048
  • — C (R) $23048
  • — Z (R) $23048

View Honeywell International INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347544702.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.