NAPERVILLE, IL —
OSHA Inspection: PERFORMANCE CONSTRUCTION AND ENGINEERING, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PERFORMANCE CONSTRUCTION AND ENGINEERING, LLC in RIVER ROAD CHESTNUT RIDGE DRIVE, NAPERVILLE, IL 60540 (NAICS 237110). OSHA activity number 347563256.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERFORMANCE CONSTRUCTION AND ENGINEERING, LLC
- Site address
- RIVER ROAD CHESTNUT RIDGE DRIVE
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60540
- Mailing
- 217 W. JOHN STREET, PLANO, IL 60545
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.652 C02 I
- Issued
- Sep 19, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $8,067 · Current $1,614 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: (a) Jobsite at River Road and Chestnut Ridge Drive, Naperville, IL 60540 - On or about June 18, 2024, the employer failed to ensure that the Efficiency Production, Inc. XLAP-66 Aluminum Shield, serial no. 149036, was assembled and installed in accordance with the manufacturer's instructions. The shield was inside an east west running trench 7.5 feet deep. A lower spreader was not installed on the west end of the shield and the three spreaders that were installed to the sidewalls were missing connecting pins thereby exposing an employee assigned work in the excavation to crushing hazards in the event of a cave-in. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $1614
- — Z (S) $8067
1926.652 G02
- Issued
- Sep 19, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.652(g)(2): Excavations of earth material to a level no greater than 2 feet (.61m) below the bottom of a shield was permitted: (a) Jobsite at River Road and Chestnut Ridge Drive, Naperville, IL 60540 - On or about June 18, 2024, the employer permitted 3 feet of earthen material to be exposed below the bottom of an Efficiency Production, Inc. XLAP-66 Aluminum Shield, serial no. 149036 prior to an employee performing work within thereby exposing the employee to crushing hazards in the event of a cave-in. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $4839
- — Z (S) $4839
More inspections at Performance Construction and Engineering, LLC
View Performance Construction and Engineering, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347563256.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.