Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDSOUTH STEEL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MIDSOUTH STEEL, INC. in 4301 ROOSEVELT HIGHWAY, ATLANTA, GA 30349 (NAICS 331110). OSHA activity number 347610743.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midsouth Steel, INC. — free Get an email when a new federal OSHA severe-injury report for Midsouth Steel, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4301 ROOSEVELT HIGHWAY
City
ATLANTA
State
GA
ZIP
30349
Mailing
4301 ROOSEVELT HWY, ATLANTA, GA 30349
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
75
Ownership type
A

4 citations on file for this inspection.

1910.242 A

Serious Gravity 5 1 instance 35 exposed
Issued
Dec 3, 2024
Abate by
Jan 2, 2025
Penalty
Initial $10,372 · Current $6,223 Reduced
29 CFR  1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:  Metabo angle grinder; throughout the production floor. On or about, July 10 2024, and time prior, the employer exposed employees to electric shock hazards in that damaged/defective power cords were not removed from the production floor.
Recent events (2)
  • — I (S) $6223.2
  • — Z (S) $10372

1910.252 B02 III

Serious Gravity 5 1 instance 25 exposed
Issued
Dec 3, 2024
Abate by
Jan 2, 2025
Penalty
Initial $10,372 · Current $6,223 Reduced
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  (a) )On or about July 10, 2024, and times prior, the employer exposed employees to ultraviolet radiation hazards in that  welding screens/welding shields were not provided for employees working in the Rail production area.
Recent events (2)
  • — I (S) $6223.2
  • — Z (S) $10372

1910.303 C03 I

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 3, 2024
Abate by
Jan 2, 2025
Penalty
Initial $6,222 · Current $3,733 Reduced
29 CFR  1910.303(c)(3)(i): Employer did not ensure all splices; joints and the free end of conductors were covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.   a) Various extension cords; throughout the production floor. On or about, July 10 2024, and times prior, the employer exposed employees to electric shock hazards in that damaged/defective power tools cords and floor fan cords were not provided with an insulation equivalent to that of the conductors.  b) Metabo 4 1/2 angle grinder; throughout the production floor. On or about, July 10 2024, and times prior, the employer exposed employees to electric shock hazards in that power cords free of damaged/defective were not provided with an insulation equivalent to that of the conductors.
Recent events (2)
  • — I (S) $3733.2
  • — Z (S) $6222

1910.305 G02 III

Serious Gravity 1 2 instances 10 exposed
Issued
Dec 3, 2024
Abate by
Jan 2, 2025
Penalty
Initial $6,222 · Current $3,733 Reduced
29 CFR  1910.305(g)(2)(iii):Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a)On or about July 10, 2024, and times prior, the employer exposed employees to electrical shock hazards in that the portable power grinder power supply cord was identified as being under stress/strain from being strung on a hook located on the inner wall.  b)On or about July 10, 2024, and times prior, the employer exposed employees to electrical shock hazards in that the yellow extension cords were identified as showing signs of stress/strain from being strung out on the production floor.
Recent events (2)
  • — I (S) $3733.2
  • — Z (S) $6222

View Midsouth Steel, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347610743.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.