Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATTICUS BAKERY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATTICUS BAKERY, LLC in 360 JAMES STREET, NEW HAVEN, CT 06513 (NAICS 311812). OSHA activity number 347648313.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atticus Bakery, LLC — free Get an email when a new federal OSHA severe-injury report for Atticus Bakery, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ATTICUS BAKERY, LLC
Site address
360 JAMES STREET
City
NEW HAVEN
State
CT
ZIP
06513
Mailing
360 JAMES STREET, NEW HAVEN, CT 06513
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
120
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 21, 2024
Abate by
Jan 10, 2025
Penalty
Initial $10,578 · Current $10,578
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  WORKSHOP: On/or about July 26, 2024 and prior to, the employer did not establish site specific hazardous energy control lockout/tagout procedures for the employees on the machinery such as but not limited to the Rheon machine.
Recent events (1)
  • — Z (S) $10578

1910.147 C06 I

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 21, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.   WORKSHOP:  On/or about July 26, 2024 and prior to, the employer did not conduct annual and/or periodic inspections of the  hazardous energy control lockout/tagout procedures for the employees on the machinery such as but not limited to the Rheon machine.
Recent events (1)
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 21, 2024
Abate by
Jan 10, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.  WORKSHOP:  On/or about July 26, 2024, and prior to,  the employer did not provide hazardous energy control lockout/tagout training for the affected employees on the machinery such as but not limited to the Rheon machine.
Recent events (1)
  • — Z (S) $0

View Atticus Bakery, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347648313.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.