LAUREL, MS —
OSHA Inspection: SOUTHERN METALS COMPANY OF MISSISSIPPI, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOUTHERN METALS COMPANY OF MISSISSIPPI, INC. in 144 DON CURT ROAD, LAUREL, MS 39440 (NAICS 332439). OSHA activity number 347666877.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN METALS COMPANY OF MISSISSIPPI, INC.
- Site address
- 144 DON CURT ROAD
- City
- LAUREL
- State
- MS
- ZIP
- 39440
- Mailing
- 144 DON CURT ROAD, LAUREL, MS 39440
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 18
- Ownership type
- A
Citations
16 citations on file for this inspection.
1910.22 A01
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. (a) Machine press area - On or about July 30, 2024, employees work in the area that has standing water on the floor from a roof leak that was not cleaned up exposing employees to slip hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.178 L01 I
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Throughout the factory - On or about July 30, 2024, the employees operating forklifts were not provided operator training, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.178 P01
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a)Throughout the facility - On or about July 30, 2024, the employer required employees to operate forklifts that needed servicing such as but not limited to backup alarms, seatbelts and operational horns, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.212 A01
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Coil fabrication area - On or about July 30, 2024, several de-coilers located in the area were not guarded to prevent employees from being exposed to moving parts.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.212 A02
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) Machine shop - On or about July 30, 2024, the employer did not ensure the floor drill was guarded at the point of operation when working with the drill exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.212 A03 II
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Press machine area - On or about July 30, 2024, employees operating the press machine where the operators two hand controls were damaged and replaced with foot control but did not guard point of operation exposing employees to amputation hazard.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.212 A03 IV D
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(d): One or more methods of machine guarding were not provided to protect the operator and other employees in the press brake area of operation (front and back) from hazards such as those created at the point of operation, and ingoing nip points: (a) Press machine area - On or about July 30, 2024, employees operating the Pacific press brakes where the guards at the front of the machines were not in place exposing employees to amputation hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.215 A04
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Machine shop - On or about July 30, 2024, employees used a bench grinder to sharpen tools with work rest more than 1/8 inch, exposing employees to caught in hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.215 B09
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) Machine shop - On or about July 30, 2024, the bench grinder used for sharpening tools was missing the tongue guard exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Throughout the facility - On or about July 30, 2024, the employees were using compressed air set at 123 p.s.i. to clean equipment and employee's clothes, exposing employees to embolism hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.303 C03 I
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. (a) Spray paint area - On or about July 30, 2024, the employer allowed the usage of a fan in the paint booth area that had the electrical cord spliced on both ends with bare wires, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.305 B02 I
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,042 · Current $1,825 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Machine shop at the south end of the shop - On or about July 30, 2024, the press machine did not have a cover for the 480-volt electrical panel, exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $1825.2
- — Z (S) $3042
1910.37 B02
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) Throughout the facility - On or about July 30, 2024, the employer did not label all exit doors, exposing employees to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A03 IV F
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(f):The point of operation of power saws whose operation exposed an employee to injury were not guarded: (a) The Machine Shop - On or about July 30, 2024, the band saw used to cut small pieces of metal did not have a guard covering the blade, exposing employees to amputation hazard
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B04 III
- Issued
- Sep 30, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least (a) Machine shop - On or about July 30, 2024, the employer had employees store Oxygen cylinders next to Argon gas cylinders exposing employees to explosive hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Sep 30, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Machine repair shop - On or about July 30, 2024, the electrical panel supply box on the north wall was blocked with material, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Southern Metals Company of Mississippi, INC.
View Southern Metals Company of Mississippi, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332439)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347666877.