WASHINGTON, DC —
OSHA Inspection: U.S. DEPARTMENT OF ARMY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of U.S. DEPARTMENT OF ARMY in 5900 MACARTHUR BLVD NW DALECARLIA CAMPUS, WASHINGTON, DC 20016 (NAICS 221310). OSHA activity number 347673071.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF ARMY
- Site address
- 5900 MACARTHUR BLVD NW DALECARLIA CAMPUS
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 5900 MACARTHUR BLVD NW DALECARLIA CAMPUS, WASHINGTON, DC 20016
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221310
- Employees
- 141
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.23 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(b)(6): The employer did not ensure that metal ladders are made with corrosion-resistant material or protected against corrosion. a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, Basin area #4, The metal fixed ladders used to access the lower levels of the basin are rusted, which weakens the structure of both the ladder and the anchor points that secure it to the concrete vertical wall. This condition exposes employees to an estimated fall hazard of 20 feet while using the ladders. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet). In addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, Employees face a potential fall hazard of approximately eight feet unto concrete and metal while monitoring the filter process. b) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, the loading dock, when not in use, exposed the employees to a fall hazard of four feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet). In addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.219 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s) a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, chemical/Gallery Building, employees are exposed to potential amputation hazards from the unguarded pulley and chain while working on or monitoring the lime machine. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(e)(1):Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, employees throughout the facilitysuch as the filter room, and pump station are exposed to an electrical shock hazard while working at or near electrical panels that are not designed nor equip to be installed in wet environments. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, Pump Building lower floor area, Employees faced a potential trip hazard while performing tasks like housekeeping and monitoring equipment due to protruding floor tiles caused by constant flooding. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, throughout the facility, the employer developed a plan but failed to train the employees in the use of portable fire suppression equipment, the hazards associated with the equipment, and the fire suppression process. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.184 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, employees throughout the facility; The employees are using alloy steel chains for rigging, maintenance, and crane operations. However, these chains are not permanently marked as required by OSHA standards, nor are they inspected beforehand to ensure they are free of potential hazards, such as stretching or broken links, before use, exposing employees to a struck-by hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet). In addition, documentation demonstrating that the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.184 E03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, throughout the facility, The employees are using alloy steel chains for rigging, maintenance, working in confined spaces, and operating cranes. However, the employer could not provide records or certifications to demonstrate that the equipment had been inspected. This lack of inspection puts employees at risk of a struck-by hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about August 7, 2024, at a worksite located at 5900 MacArthur Blvd NW, Employees in the facility were exposed to an electrical shock hazard while working near electrical equipment that had missing knockouts in both dry and wet environments. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at U.S. DEPARTMENT OF ARMY
FORT DETRICK, MD—2026-04-17
U.S. DEPARTMENT OF ARMY
FORT LIBERTY, NC—2024-10-02 00:00:00
U.S. DEPARTMENT OF ARMY
WASHINGTON, DC—2024-08-07 00:00:00
U.S. DEPARTMENT OF ARMY
FORT DETRICK, MD—2023-10-11 00:00:00
U.S. DEPARTMENT OF ARMY
CLEVELAND, GA—2022-08-10 00:00:00
U.S DEPARTMENT OF ARMY
View U.S. DEPARTMENT OF ARMY's full OSHA safety record →
More inspections in this industry (NAICS 221310)
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
ROYAL OAK, MI—2026-07-15
SOUTHEASTERN OAKLAND COUNTY WATER AUTHORITY
CARTHAGE, TN—2026-07-10
SMITH UTILITY DISTRICT WATER TREATMENT PLANT
PATERSON, WA—2026-07-10
WA317992032 - COLUMBIA WATER & POWER DISTRICT
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347673071.