Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METEOR SEALING SYSTEMS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of METEOR SEALING SYSTEMS, LLC in 400 S. TUSCARAWAS AVENUE, DOVER, OH 44622 (NAICS 326291). OSHA activity number 347676991.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meteor Sealing Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Meteor Sealing Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
400 S. TUSCARAWAS AVENUE
City
DOVER
State
OH
ZIP
44622
Mailing
400 S. TUSCARAWAS AVENUE, DOVER, OH 44622
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
326291
Employees
400
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 3 instances 15 exposed
Issued
Dec 19, 2024
Abate by
Feb 26, 2025
Penalty
Initial $11,524 · Current $9,219 Reduced
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  a. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 2 and Line 4 Microwave had the specific steps for shutting down the machinery. As a result, employees were exposed to caught-in and struck-by hazards.  b. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 5 Extruder 1 and Extruder 2 had the specific steps for shutting down the machinery. As a result, employees were exposed to caught-in and struck-by hazards.  c. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 5 Microwave had the specific steps for shutting down the machinery. As a result, employees were exposed to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $9219.2
  • — Z (S) $11524

1910.147 C04 II D

Serious Gravity 5 3 instances 15 exposed
Issued
Dec 19, 2024
Abate by
Feb 26, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(D): Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  a. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 2 and Line 4 Microwave had the specific steps for how to verify the effectiveness of the control measures for the hazardous energy sources. As a result, employees were exposed to caught-in and struck-by hazards.  b. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 5 Extruder 1 and Extruder 2 had the specific steps for how to verify the effectiveness of the control measures for the hazardous energy sources. As a result, employees were exposed to caught-in and struck-by hazards.  c. On or about August 8, 2024, and at times prior, the employer did not ensure that the energy control procedure for Line 5 Microwave had the specific steps for how to verify the effectiveness of the control measures for the hazardous energy sources. As a result, employees were exposed to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 4 instances 15 exposed
Issued
Dec 19, 2024
Abate by
Feb 26, 2025
Penalty
Initial $16,131 · Current $12,905 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a. On or about August 8, 2024, and at times prior, the employer did not ensure that periodic inspections of the energy control procedures as well as the associated authorized employees including, but not limited to, Line 2 and Line 4 Microwave were conducted at least annually. As a result, employees were exposed to caught-in/between and struck by hazards.  b.  On or about August 8, 2024, and at times prior, the employer did not ensure that periodic inspections of the energy control procedures as well as the associated authorized employees including, but not limited to, Line 5 Extruder 1 and Extruder 2 were conducted at least annually. As a result, employees were exposed to caught-in/between and struck by hazards.  c. On or about August 8, 2024, and at times prior, the employer did not ensure that periodic inspections of the energy control procedures as well as the associated authorized employees including, but not limited to, Line 5 Rubber Feeder 1 and Rubber Feeder 2 were conducted at least annually. As a result, employees were exposed to caught-in/between and struck by hazards.  d. On or about August 8, 2024, and at times prior, the employer did not ensure that periodic inspections of the energy control procedures as well as the associated authorized employees including, but not limited to, Line 5 Microwave were conducted at least annually. As a result, employees were exposed to caught-in/between and struck by hazards.
Recent events (2)
  • — I (S) $12904.8
  • — Z (S) $16131

1910.147 C07 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 19, 2024
Abate by
Feb 26, 2025
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a. On or about August 8, 2024, and at times prior, the employer did not ensure that all authorized employees performing maintenance and servicing work plant-wide including, but not limited to, Extrusion Line setup, Extruder screw changes/cleaning, and preventative and reactive maintenance on the extrusion lines, were trained on the recognition of applicable energy sources, the type and magnitude of energy exposed to, and the methods and means necessary for energy isolation and control. As a result, employees were exposed to caught-in/between and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1910.147 D

Serious Gravity 10 2 instances 8 exposed
Issued
Dec 19, 2024
Abate by
Feb 26, 2025
Penalty
Initial $16,131 · Current $12,905 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a. On or about December 4, 2024, and at times prior, on Extrusion Line 5, employees were exposed to machine hazards associated with being struck-by or caught-in hazards of the machinery while performing maintenance and servicing tasks such as, but not limited to, set-up, die changes, and adjustments. The employer did not implement energy control application steps as the extrusion line was not isolated from its energy sources prior to performing the maintenance and servicing task [per the 1910.147(d)(3) requirements]. As a result, the remaining applicable energy control elements, including lockout/tagout device application [(d)(4)], dissipation of residual and/or stored energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  b. On or about November 26, 2024, and at times prior, on Extrusion Line 5, employees were exposed to machine hazards associated with being struck-by or caught-in hazards of the extruder screw and associated heat and water lines, while performing maintenance and servicing tasks such as, but not limited to, extruder screw changeovers. The employer did not implement energy control application steps as the extrusion line was not shutdown prior to performing the maintenance and servicing task [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, including machine and equipment isolation [(d)(3)], lockout/tagout device application [(d)(4)], dissipation of residual and/or stored energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  c. On or about August 8, 2024, and at times prior, on Extrusion Line 4, employees were exposed to machine hazards associated with being struck-by or caught-in hazards of the extruder screw and associated heat and water lines, while performing maintenance and servicing tasks such as, but not limited to, extruder screw changeovers. The employer did not implement energy control application steps as the extrusion line was not shutdown prior to performing the maintenance and servicing task [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, including machine and equipment isolation [(d)(3)], lockout/tagout device application [(d)(4)], dissipation of residual and/or stored energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $12904.8
  • — Z (S) $16131

1910.147 F03 II D

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.  a. On or about August 8, 2024, and at times prior, the employer did not ensure that each authorized employee performing maintenance and servicing work on Extrusion Line 2 affixed their own personal lockout/tagout devices. As a result, employees were exposed to caught-in/between and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.178 L01 II

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2024
Abate by
Dec 31, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).  a. On or about August 8, 2024, and at times prior, the employer permitted an untrained employee to operate the Mitsubishi Model FGC70K (Serial No. AF8900232) by Extrusion Line 2. As a result, employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.184 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2024
Penalty
Initial $11,524 · Current $9,219 Reduced
29 CFR 1910.184(c)(1): Slings that are damaged or defective shall not be used.  a. On or about August 8, 2024, and at times prior, the employer utilized a damaged synthetic web sling on Extrusion Line 2 to hoist the gear box for removal utilizing a forklift. As a result, employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $9219.2
  • — Z (S) $11524

1910.184 I09 III

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.184(i)(9)(iii): Snags, punctures, tears or cuts;   29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present:  a. On or about August 8, 2024, and at times prior, a synthetic web sling that had snags and tears was not removed from service and was in use on Extrusion Line 2 to remove a gear box. As a result, employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 D

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 19, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.184(d): Inspections. Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service.  a. On or about August 8, 2024, and at times prior, the employer did not ensure that the various slings utilized on Extrusion Line 2 to remove the gear boxes were inspected prior to usage. A damaged synthetic web sling was observed in use. As a result, employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II D

Other-than-serious 1 instance 3 exposed
Issued
Dec 19, 2024
Abate by
Dec 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s).  a. On or about August 8, 2024, the employer did not ensure that the lockout/tagout device in use on Extrusion Line 2 indicated the identity of the employee who applied the device. As a result, employees were exposed to caught-in/between and struck-by hazards associated with unexpected energization of Extrusion Line 2.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0