OSHA Inspection: CF&I STEEL, L.P.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CF&I STEEL, L.P. in 2100 S. FREEWAY, PUEBLO, CO 81004 (NAICS 331110). OSHA activity number 347679698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CF&I Steel, L.P. — free Get an email when a new federal OSHA severe-injury report for CF&I Steel, L.P. is published. One employer, no account, unsubscribe in one click.
Establishment
CF&I STEEL, L.P.
Site address
2100 S. FREEWAY
City
PUEBLO
State
CO
ZIP
81004
Mailing
1612 E. ABRIENDO AVE., PUEBLO, CO 81004
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
230
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Rail Mill, North stamp wheel:  On or about August 9, 2024, and at times prior, the employer did not ensure that employees engaged in maintenance activities utilized energy control procedures to isolate and de-energize the sled while the face plate was removed to replace a retaining pin on the north stamp wheel. This condition exposed employees to caught-between and crushed-by hazards resulting in a fatality.
Recent events (1)
  • — Z (S) $16550

1910.147 D02

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) Rail Mill, North Stamp Wheel: On or about August 9, 2024, and at times prior, the employer did not ensure the sled and north stamp wheel was shut down for maintenance procedures prior to removing the face plate to replace a retaining pin. This condition exposed employees to caught between and crushed by hazards resulting in a fatality.
Recent events (1)
  • — Z (S) $0

1910.147 D06

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished:  (a) Rail Mill, North stamp wheel: On or about August 9, 2024 , and at times prior, employees replacing a retaining pin on the North stamp wheel did not verify that the sled had been isolated and deenergized. This condition exposed employees to caught-between and crushed-by hazards resulting in a fatality.
Recent events (1)
  • — Z (S) $0

1910.147 F03 II D

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  (a) Rail Mill, North stamp wheel: On or about August 9, 2024, and at times prior, the employer did not ensure that each authorized employee locked out before working on the north stamp wheel. Employees replacing a retaining pin on the stamp wheel did not affix their personal locks to the group lock box prior to working on the wheel.  This condition exposed employees to caught-between and crushed-by hazards resulting in a fatality.
Recent events (1)
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $15,606 · Current $15,606
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:  (a) Rail Mill, North stamp wheel: On or about August 9, 2024, and at times prior, the employer did not ensure that energy control procedures included the specific procedural steps for the placement and removal of lockout devices, and specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices. This condition exposed employees to caught-between and crushed-by hazards.
Recent events (1)
  • — Z (S) $15606

1910.147 C07 I A

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  (a) Rail Mill, North stamp wheel: On or about August 9, 2024, and at times prior, the employer did not ensure that authorized employees received training on the methods necessary to isolate the sled and stamp wheels. Employees replacing a retaining pin on the north stamp wheel were exposed to caught-between and crushed-by hazards.
Recent events (1)
  • — Z (S) $16550

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 3, 2025
Abate by
Mar 4, 2025
Penalty
Initial $13,005 · Current $13,005
29 CFR  1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  (a) Rail mill electrical room: On or before August 9, 2024, and at times prior the employer did not ensure that maintenance electrical technicians wore appropriate electrical protective equipment when locking out energized 480-volt electrical circuits. Employees opened and closed a knife switch on the stamp wheel electrical panel (CP-6C) in close proximity to energized conductors without personal protective equipment such as an arc-rated face shield, arc-rated balaclava and voltage rated gloves. This condition exposed the employees to hazards such as shock, electrocution, arc blast, and arc flash.
Recent events (1)
  • — Z (S) $13005

View CF&I Steel, L.P.'s full OSHA safety record →