NEWARK, NJ ·
OSHA Inspection: OXFORD AIRPORT TECHNICAL SERVICES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OXFORD AIRPORT TECHNICAL SERVICES in 3 BREWSTER RD, #A, NEWARK, NJ 07114 (NAICS 488119). OSHA activity number 347699944.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OXFORD AIRPORT TECHNICAL SERVICES
- Site address
- 3 BREWSTER RD, #A
- City
- NEWARK
- State
- NJ
- ZIP
- 07114
- Mailing
- 3 BREWSTER RD, #B, NEWARK, NJ 07114
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488119
- Employees
- 70
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Dec 12, 2024
- Penalty
- Initial $13,828 · Current $9,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:( A) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 /Conveyor System - The employer did not develop lock out procedures to assist employees engaged in maintenance and or service activities. This condition exposed the employees to caught in hazards. Incident occurred on August 12, 2024
Recent events (2)
- · I (S) $9679.6
- · Z (S) $13828
1910.147 C06 I
- Issued
- Dec 12, 2024
- Abate by
- Jan 9, 2025
- Penalty
- Initial $13,828 · Current $9,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 / Conveyor System - The employer failed to conduct periodic inspections of the energy control procedures and its authorized employees to ensure that the procedures and requirements were being followed. Incident occurred August 12, 2024
Recent events (2)
- · I (S) $9679.6
- · Z (S) $13828
1910.147 D04 I
- Issued
- Dec 12, 2024
- Penalty
- Initial $16,131 · Current $11,292 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) Oxford Airport Technical Services - 3 Brewster Rd, #B NEWARK, NJ 07114 - The employer did not ensure that the conveyor system was locked out prior to service being performed, causing employee to be injured by caught in hazard. Incident occurred on August 12, 2024
Recent events (2)
- · I (S) $11291.7
- · Z (S) $16131
More inspections at Oxford Airport Technical Services
View Oxford Airport Technical Services's full OSHA safety record →
More inspections in this industry (NAICS 488119)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347699944.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.