Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERMO KING CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THERMO KING CORPORATION in 1800 CENTENNIAL AVENUE, HASTINGS, NE 68901 (NAICS 333415). OSHA activity number 347700932.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermo King Corporation — free Get an email when a new federal OSHA severe-injury report for Thermo King Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1800 CENTENNIAL AVENUE
City
HASTINGS
State
NE
ZIP
68901
Mailing
1800 CENTENNIAL AVENUE, HASTINGS, NE 68901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
500
Ownership type
A

2 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 9, 2024
Abate by
Jan 13, 2025
Penalty
Initial $6,913 · Current $6,913
29 CFR  1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used:  Employees are exposed to eye injury hazards due to ultraviolet light exposure. This was most recently documented on or about August 20, 2024 at 1800 Centennial Avenue, Hastings, Nebraska. Employees working as grinders in the aluminum department were not protected from welding flash from the adjacent welding areas.
Recent events (2)
  • — I (S) $6913
  • — Z (S) $6913

1910.307 C

Deleted Serious Gravity 5 2 instances 8 exposed
Issued
Dec 9, 2024
Abate by
Jan 13, 2025
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR  1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  Employees are exposed to combustion hazards. This was most recently documented on or about August 20, 2024 at 1800 Centennial Avenue, Hastings Nebraska. Aluminum dust was being created in the grinding booth area.  Electrically powered equipment within the grinding booth area was not approved for use in a Class II Division II in the following but not limited to.  A) Guardair Vacuum model N551BCX B) Dakason 8FT LED lights
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

View Thermo King Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347700932.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.