WILMINGTON, DE —
OSHA Inspection: THE PEP BOYS - MANNY, MOE, & JACK OF DELAWARE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THE PEP BOYS - MANNY, MOE, & JACK OF DELAWARE, LLC in 729 PHILADELPHIA PIKE, WILMINGTON, DE 19809 (NAICS 811111). OSHA activity number 347720302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PEP BOYS - MANNY, MOE, & JACK OF DELAWARE, LLC
- Site address
- 729 PHILADELPHIA PIKE
- City
- WILMINGTON
- State
- DE
- ZIP
- 19809
- Mailing
- 729 PHILADELPHIA PIKE, WILMINGTON, DE 19809
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 A04
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $15,606 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) 729 Philadelphia Pike Wilmington, DE 19809 (rear wall): On or about August 29, 2024, the employer failed to ensure safeguards such as missing or damaged ceiling tiles were in place which are required to provide a barrier against the spread of smoke and fire. Properly installed ceiling tiles allow smoke detectors, heat detectors, and sprinkler systems to operate correctly in the event of fire. b) 729 Philadelphia Pike Wilmington, DE 19809 (adjacent to bathroom/front door): On or about August 29, 2024, CSHO observed emergency exit hazards related to emergency evacuation of the building, the emergency lighting located at the front entrance door and adjacent to the employee bathroom had emergency lighting bulbs that were blown and nonfunctional. The inadequate maintenance of the emergency lighting failed to ensure visibility in the event of an emergency evacuation.
Recent events (3)
- — F (S) $0
- — C (S) $15606
- — Z (S) $15606
1910.303 G01 II
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $10,403 · Current $10,403
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) 729 Philadelphia Pike Wilmington, DE 19809 (rear wall): On or about August 29, 2024, CSHO observed two panels listed as P2-1 "caution high leg" and panel P2-2 with a red craftsman tool chest holding a microwave and Keurig coffee maker plugged in with the coffee maker cord going across the front of the access panel plugged in to the ac outlet. Access to the electrical equipment was not maintained to permit ready and safe operation in that the space around the 240V equipment was used for storage. b) 729 Philadelphia Pike Wilmington, DE 19809 (rear wall): On or about August 29, 2024, CSHO observed access to the electrical equipment was not maintained to permit ready and safe operation in that the space around the 480V equipment was used for storage to include but not limited to automobile tires.
Recent events (3)
- — F (O) $10403
- — C (S) $10403
- — Z (S) $10403
1910.1200 E01 I
- Issued
- Feb 18, 2025
- Abate by
- Mar 10, 2025
- Penalty
- Initial $15,606 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) 729 Philadelphia Pike Wilmington, DE 19809: On or about August 29, 2024, the employer did not maintain a chemical inventory list identifying the hazardous chemicals being used by their employees.
Recent events (3)
- — F (S) $0
- — C (S) $15606
- — Z (S) $15606
1910.1200 E04
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(4): The employer did not make the written hazard communication program available upon request to the Assistant Secretary and the Director in accordance with 29 CFR 1910.1020(e): a) 729 Philadelphia Pike Wilmington, DE 19809: On or about August 29, 2024, the employer did not provide the written or electronic formatted written hazard communication program element (1910.1200 (g) Safety Data Sheet) upon request.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $0 · Current $15,606
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) 729 Philadelphia Pike Wilmington, DE 19809 (Shop Floor): On or about August 29, 2024, the employer did not provide containers with appropriate labeling as required by the Global Harmonized System (GHS) to identify product stored in containers. Product stored in containers did not have the appropriate product identifier, pictogram, or signal word (corrosive, danger, explosive) in conjunction with safety data sheets for worker safety.
Recent events (3)
- — F (O) $15606
- — C (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical a) 729 Philadelphia Pike Wilmington, DE 19809: On or about August 29, 2024, and at times prior thereto, employees who use hazardous chemicals such as, but not limited to oil(s), transmission fluid, gasoline, wastewater, antifreeze, acetylene, oxygen, solvents, and degreasers were not provided the safety data sheet (SDS) for the chemical placed in their work area.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H02 III
- Issued
- Feb 18, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200: a) 729 Philadelphia Pike Wilmington, DE 19809: On or about August 29, 2024, and at times prior thereto, employees who use hazardous chemicals such as, but not limited to oil(s), transmission fluid, gasoline, wastewater, antifreeze, acetylene, oxygen, solvents, and degreasers were not provided the location and availability of the written hazard communication program.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1904.39 A02
- Issued
- Feb 18, 2025
- Penalty
- Initial $13,005 · Current $10,400 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. a) 729 Philadelphia Pike Wilmington, DE 19809: On or about August 29, 2024, the employer did not report an in-patient hospitalization within 24 hours from August 26, 2024.
Recent events (3)
- — F (O) $10400
- — C (O) $13005
- — Z (O) $13005
More inspections at The PEP Boys - Manny, MOE, & Jack of Delaware, LLC
View The PEP Boys - Manny, MOE, & Jack of Delaware, LLC's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347720302.